INSTRUCTIONS MANUAL
West 42nd St., New York, NY 10036, Telephone (212) 642-4900, Fax (212) 398-0023 -
www.ansi.org
CAUTION: This equipment should be used in locations with mechanical ventilation
that provides at least four air changes per hour or the equipment should be located
at least 18 inches (457 mm) above the floor," or the equivalent.
CAUTION: Do not pressure test or leak test HFC-134a service equipment and/or
vehicle air conditioning systems with compressed air. Some mixtures of air and
HFC-134a have been shown to be combustible at elevated pressures. These
mixtures, if ignited, may cause injury or property damage. Additional health and
safety information may be obtained from refrigerant manufacturers.
CAUTION: Should be operated by certified personnel.
WARNING: There is the possibility of refrigerant contamination in the mobile A/C
system being serviced or refrigerant container.
NOTE: Use only new lubricant to replace the amount removed during the recycling
process. Used lubricant should be discarded per applicable federal, state, and local
requirements.
INTRODUCTION
This machine is ETL Laboratories approved, in compliance with
SAE J2788.
We are dedicated
to solving the issues surrounding the safe containment and proper management of refrigerants.
Your new machine incorporates the latest technology and state of the art features to aid you in
servicing HFC134a air conditioning and refrigeration systems. We hope you get as much
enjoyment using this equipment as we did designing and building it
CERTIFICATION
All technicians opening the refrigeration circuit in automotive air conditioning systems must now
be certified in refrigerant recovery and recycling procedures to be in compliance with Section
609 of the Clean Air Act Amendments of 1990. For information on certification call MACS
Worldwide at (215) 631-7020
.
ABOUT THIS MANUAL
This manual includes a SAFETY SUMMARY, MACHINE PREPARATION FOR USE,
OPERATION procedures, and MAINTENANCE instructions, for your Air Conditioning Service
Center. Anyone intending to use the machine should become familiar with ALL the information
included in this manual (especially the SAFETY SUMMARY) before attempting to use it.
Before operating this machine for the first time, perform all PREPARATION FOR USE
instructions. If your new machine is not properly prepared to perform a service, your service
data could be erroneous. In order to properly perform a complete air conditioning service,
follow all procedures in the order presented. Please take the time to study this manual before
operating the machine. Then keep this manual close at hand for future reference. Please pay
close attention to the SAFETY SUMMARY and all WARNINGS and CAUTIONS provided
throughout this manual. To activate the published warranty, mail the attached warranty card.
CAUTION: The machine is intended for indoor use only.
ABOUT YOUR CLIMA/CS AIR CONDITIONING SERVICE CENTER
Your machine incorporates a highly accurate electronic scale for determining charging weights,
etc. Other functions can also be performed with the electronic scale as you will discover during
the operating procedures. Either standard or metric units of measure can be selected. Your
new machine has been designed specifically to use R-134a, to operate within the objectives of
the Montreal Protocol.