Recovery And Recycling - MasterCool 69789 Instrucciones Para El Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Press F4 ↵ to continue
Since hybrid was selected, the hose flushing procedure will need to be performed to ensure that no cross contamination will occur. Select hose
flushing and press F4 ↵.
F1 to continue
F1 to continue
Hose flushing consists of 4 cleaning rounds. At the end of the 4 phases, the following screen will be displayed.
NOTE: The hose flushing process takes approximately 10 minutes to complete. Due to the safety issues related to hybrid vehicles, do not stop this
process.

RECOVERY AND RECYCLING

Connect the hoses to the A/C system with the quick-connect couplings, bearing in mind that BLUE must be connected to the low-pressure side and
RED to high pressure. If the A/C system is equipped with a single quick-connect coupling for high or low pressure, connect only the relative hose.
Check that the high- and low-pressure taps are closed. Start the vehicle engine and the air conditioner and allow both to run for 5 to 10 minutes
use specific oil
with a separate
device
Press ENTER
Gas Filling
ASSISTED PROCEDURE
Hose Flushing
Recovery/Recycling
Vacuum
Ref Charge
HP & LP HOSES
FLUSHING PROCEDURE
F1 to continue
F2 to exit
Connect and open HP
and LP hoses to the side of the machine
F1 to continue
F2 to exit
HOSE FLUSHING
PLEASE WAIT
ACP >26 inHg
HOSE FLUSHING
END OF SEQUENCES
F2 to exit
xxg
xx.xx lb
19