Normal Display Mode - Key Automation CT-724 Instrucciones Y Advertencias Para Su Instalación Y Uso

Central 24vcc para un motor corredizo, basculante o barrera 24 vcc, con gestión codificador
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
CONNECTION FOR SAFETY AND CONTROLS
sCA
status indicator light, 24 V, 50 mA max, between sCA and -
CO
safety edge, On/OFF contact between CO and C (attention, with dip switch 1 On it disables EDGE safety input)
F1
Photocells (closing), NC contact between F1 and C (attention, with dip switch 3 ON it disables PHOTOCELL 1 safety input)
Photocells will work at any time during closing of the automation, causing an immediate stop and reversing the direction of
movement
F2
Photocells (opening), NC contact between F2 and C (attention, with dip switch 2 ON it disables PHOTOCELL 2 safety input)
Photocells will work at any time during opening of the automation, causing an immediate stop, the automation will continue
only contact is reactivated.
ST
NC contact safety STOP between ST and C (attention, with dip switch 4 ON it disables STOP safety input)
This input is considered a safety; the contact can be deactivated at any time immediately stopping the automation, disabling
any function including Automatic Closing.
OP
Contact OPEnInG NO input between OP and C. Contact for MAN PRESENT function. The gate OPEns as long as the con-
tact is pressed.
CL
Contact CLOsInG NO input between CL and C. Contact for MAN PRESENT function. The gate CLOSES as long as the
contact is pressed.
PE
PEDESTRIAN input nO contact between PE and C. Partial opening input set with programming.
PP
STEP/STEP input nO contact between PP and C. Open/stop/Close/stop input set with programming.
C
Common for CO, F1, F2, ST, OP, CL, PE, PP inputs
CH2
Channel 2 receiver contact nO at rest
CH2
Channel 2 receiver contact nO at rest
A sig
Antenna - signal -
A gnd
Antenna - shield -
4.2 - Normal mode display
4.2 - Normal mode display
In "NORMAL MODE", when the installation is powered normally, the 3-digit LCD display shows the following status messages:
INDICATIONS
MEAnInG
Gate closed or restart after shutdown
Opening gate
Opening gate stopped
Closing gate
Closing gate stopped
Gate stopped by external event
Gate stopped without auto-reclosing
-
Open gate waiting for auto-reclosing, with dash indicates countdown
Pedestrian gate waiting for auto-reclosing
Open gate waiting for auto-reclosing, the last 10 seconds are shown in the fi rst character on the left
In addition, the dot between the above fi gures show the status of the limit switches as described below:
INDICATIONS
MEAnInG
Limit switch CLOSED (one dot before the fi rst digit)
.
Limit switch OPEn (one dot between the two digits)
.
no limit switch on (no dots)
En
19
Tabla de contenido