RS Pro RS-9663 Manual De Instrucciones página 6

Tabla de contenido
Heavy Duty True RMS Digital Multimeter / English
5-5. AC Current (Frequency, Duty Cycle) Measurements
CAUTION: Do not make 20 A current measurements for longer than 30 seconds.
Exceeding 30 seconds may cause damage to the meter and/or the test leads.
1. Insert the black test lead banana plug into the
negative COM jack.
2. For current measurements up to 6000 μA AC, set
the function switch to the μA position and insert the
red test lead banana plug into the μA/mA jack.
3. For current measurements up to 600 mA AC, set the
function switch to the mA position and insert the red
test lead banana plug into the μA/mA jack.
4. For current measurements up to 20 A AC, set the
function switch to the 10A/HZ/% position and insert
the red test lead banana plug into the 10A jack.
5. Press the MODE button to indicate "AC" on the
display.
6. Remove power from the circuit under test, then open
up the circuit at the point where you wish to measure
current.
7. Touch the black test probe tip to the neutral side of
the circuit.
Touch the red test probe tip to the "hot" side of the
circuit.
8. Apply power to the circuit.
9. Read the current in the display.
10. Press the Hz/% button to indicate "Hz".
11. Read the frequency in the display.
12. Press the Hz/% button again to indicate "%".
13. Read the % duty cycle in the display.
14.Press the Hz/% button to return to current
measurement.
8
5-6. Resistance Measurements
WARNING: To avoid electric shock, disconnect power to the unit under test and
discharge all capacitors before taking any resistance measurements. Remove the
batteries and unplug the line cords.
1. Set the function switch to the
2. Insert the black test lead banana plug into the negative
COM jack.
Insert the red test lead banana plug into the positive "Ω" jack.
3. Press the MODE button to indicate "Ω" on the display.
4. Touch the test probe tips across the circuit or part under
test. It is best to disconnect one side of the part under test
so the rest of the circuit will not interfere with the resistance
reading.
5. Read the resistance in the display.
8