GENERATOR SET OVERLOAD
Never exceed the rated power capacity (Amperes and/or Watts) during continuous opera-
tion. Before connecting and running the generator set, calculate the electrical power con-
sumption of the electrical equipment (in Watts or Amperes). This electrical power (in Watts
and/or Amperes) is generally found on the identification plate of bulbs, electrical appliances,
motors, etc. The total of all the powers of the equipment used should not exceed at any one
time the rated power of your generator set
Note: an electrical appliance (compass saw, drill, etc.) consumes more Watts or Amperes
than the number specified on the identification plate when the motor is subjected to difficult
use. For example, a saw that is to cut an extremely hard material consumes 3 to 4 times
more Watts or Amperes than the number specified on its identification plate.
STARTING UP, OPERATING AND SHUTTING DOWN THE GENERATOR SET
Starting of the power generating unit :
1- Turn the fuel cock lever to the «on» position
2- Turn the engine switch to the «on»
position
3- Turn the choke lever to the
position
N.B : The choke is not required to start a warm engine.
4- Pull slowly on the recoil starter until its engaged, then pull it brisky.
5- Warm up the engine.
6-Turn the choke lever back to the operating position.
!
Before starting the engine, do not connect the electric apparatus.
N.B : «-»means below. .
Aplication wattage indicate when each apparatus is used by itself.