SYSTEM FOR AN OPEN/CLOSED TANK INSTALLATION
AN EXAMPLE OF A HYDRAULIC SYSTEM FOR A THERMO FIREPLACE THAT PRODUCES AND STORES HOT SANITARY WATER AND HAS A WALL MOUNTED BOILER
TM
IDROKIT is designed to facilitate the work carried out by the installers. In fact, it consists of all the necessary components for the product
to be properly installed.
1
3
6
8
cm 44
cm 45
THE INLET AND OUTLET PIPES MUST BE CROSSED FOR THIS TO FUNCTION PROPERLY
IDROKIT
10
2
4
5
9
7
11
A
B
D
E
F
ACS:
Hot Sanitary Water
AF:
Cold Water
AL:
Water Mains Supply
C:
Filling/Top-Up Section
CE:
Electronic Panel
EV:
3-way Solenoid Valve
NA:
Normally Open
NC:
Normally Closed
GR:
Pressure Reducer
Ja:
Automatic Relief Valve
Jm:
Manual Relief Valve
MI:
System Flow
MT:
Thermostatic Mixer
P:
Pump (circulator)
RA:
Radiators
RI:
System Return
S:
Drain
SC30:
30-plate Heat Exchanger
ST:
Temperature Sensor
TC:
Contact Thermostat
TM:
Thermo Fireplace
V:
Ball Valve
Vea:
Open Expansion Tank
Vec:
Closed Expansion Tank
VR:
Check Valve
VSPT:
Safety Pressure and Temperature Valve
VCA:
Boiler
1
heating return
2
gas boiler hot sanitary water
3
thermo fireplace flow
4
drain
5
hot sanitary water
6
thermo fireplace return
7
heating flow
8
water mains
9
thermostatic mixer setting
10
synoptic panel
11
auxiliary socket for a room thermostat
A 30-plate Heat Exchanger
B primary circulator (in the wood-fired version)
C 50-litre boiler
D heating system circulator
E closed expansion tank
C
F fireplace covering for exposed installation
IDROKIT