Cleaning the debris collection bag
Prerequisite: The tank is open. (→ Opening/closing the tank)
How to proceed:
J
1. Release the Velcro tape of the debris collection bag.
2. Pull the elastic of the debris collection bag from the intake distributor.
3. Remove and empty the debris collection bag.
– Undo the zip on the debris collection bag to facilitate emptying.
– Close the zip after emptying.
4. Refit the debris collection bag in the reverse order.
– Secure the debris collection bag with the Velcro tape.
Cleaning the foam filter
Prerequisite: The tank is open. (→ Opening/closing the tank)
How to proceed:
K
1. Release the filter cover (bayonet closure).
2. Pull off the foam filter and clean with clean water and a soft brush.
3. Check the function of the float and clean if necessary.
– Ensure that the float can move freely and easily.
4. Assemble the parts in the reverse order.
Cleaning the non-return valve
Prerequisite: The tank is open. (→ Opening/closing the tank)
How to proceed:
L
1. Unscrew the Storz coupling type C.
2. Turn the adapter away to the side.
3. Unscrew the adapter.
4. Remove the non-return valve.
5. Clean all parts with clean water and a soft brush.
6. Reassemble the parts in the reverse order.
– Important: Ensure that the non-return valve is inserted such that the valve opens in the direction of the outlet.
Removing/cleaning the pump
Prerequisite: The tank is open. (→ Opening/closing the tank)
How to proceed:
M
1. Unscrew the plug connection and pull apart.
– Protect the open plug connection from moisture.
2. Unscrew the Storz coupling type C.
3. Turn the adapter away to the side.
4. Remove the transport protection.
5. Carefully bend open the retaining brace with the tab to release.
6. Remove the discharge pump and clean or replace if defective.
7. Cleaning the discharge pump:
– Undo the screws on the pump casing and remove the protection grid.
– Clean the protection grid and pump casing on the inside and outside with clear water and a soft brush.
– Remove soiling from the impeller unit, turning the impeller unit by hand to access all soiled points.
8. Reassemble the parts in the reverse order.
– The transport protection only needs to be fitted for shipping or horizontal transport of the unit.
- EN -
23