Connecting the power supply
How to proceed:
 E
Unit version with power plug:
• Push the coupling of the power cable onto the unit plug.
 F
Unit version with power cable:
• Connect the unit to the power supply.
– Work on the power supply may only be carried out by a qualified electrician.
– Adhere to the pin assignment specified on the power cable label.
– Only use wires with wire end ferrules for connection.
Connecting an EGC-compatible device
The correct fastening of the plug connector is important for a secure connection and an interference-free EGC network.
An EGC connection cable is necessary for connection.
• The EGC connection cable is available as an accessory in the lengths 2.5 m (47038), 5 m (47039) and 10 m (47040).
How to proceed:
 G, H
1. Remove the EGC terminal resistor from the unit.
2. Fit the plug connector and secure with the two screws (max. 2.0 Nm).
– Ensure that the rubber seal is clean and fits exactly.
– Replace the rubber seal if damaged.
3. Remove the protection cap from EGC-OUT of the last unit in the EGC network, fit the terminal resistor EGC and se-
cure it with the two screws (max. 2.0 Nm).
– Ensure that on EGC-OUT of the last unit in the EGC network, the terminal resistor EGC is installed instead of an
EGC connection cable, to ensure that the EGC network is closed off properly.
– The scope of delivery of InScenio FM-Master EGC or InScenio EGC Controller each contains a terminal resistor
EGC.
N O T E
For further information regarding the operation and integration into the EGC system, please refer to the in-
structions for use of the FM Master EGC at http://www.oase-livingwater.com/egc-start.
Connect the units to the power supply distributor
How to proceed:
1. Choose a suitable socket (see fig. above) and insert the unit power plug into the socket.
– Ensure that it is permissible to connect the unit to this socket. For this purpose, consult the operating manual of
the unit you wish to connect.
– Units powered via a transformer may not be connected to the socket with the dimmer function.
– Do not connect EGC-capable units to the socket with the dimmer function, otherwise they will be damaged.
 I
2. Fit the protection hood.
1 Socket 1, switchable (max. 10 A / 2000 W)
2 Socket 2, switchable (max. 10 A / 2000 W)
3 Socket 3, switchable (max. 10 A / 2000 W)
4 Socket 4, switchable and dimmable (40 W ... 320 W)
Note: Ensure that the total output of 16 A / 3600 W is not exceeded!