8.2.2 Teach Function

1. In the programming menu, programme MPI
input 1 or MPI input 2 (MP.INP.1 / MP.INP.2)
to TEACH
2. In operating mode, select the preset to be
changed: PRES1 or PRES2
3. In operating mode, briefly activate MPI input 1
or MPI input 2 (NPN or PNP input logic)
the current count value will be adopted as
the new preset value
See also 9. Error messages.
The preset value can subsequently be
further modified via the keypad. If preset
entry is inhibited (see note 8.2.1), then the
Teach Function is also locked out.

8.2.3 Teach-In with tracking presets

If a tracking (trailing) preset (TRAIL or TR.AR) has
been programmed, the value for Preset 2 can be
set either via the keypad or via the Teach-In
function.
However the value for Preset 1 must be entered via
the keypad. In this instance, it is not possible to use
the Teach-In function.
.
With output operations ADD.BAT,
SUB.BAT, ADD.TOT, SUB.TOT, TRAIL
and TR.AR, the Teach-In function is not
available for Preset 1.
8.3

Set Function

The pulse counter and the timer can be set to a
value by means of the Set function.
1. In the programming menu, programme MPI
Input 1 or MPI Input 2 (MP.INP1 / MP.INP2)
to SET
2. In the programming menu, set the parameter
SETPT to the desired value
3. In operating mode, briefly activate MPI input 1
or MPI input 2 (NPN or PNP input logic)
For add. output operations the pulse
counter or timer will be set to the SETPT
value
For sub. output operations the pulse
counter or timer will be set to the
difference between the value of Preset 2
and the value of SETPT
See also 9. Error messages
Page 16
8.4

Default Parameters

Note: Three default parameter sets have
been permanently stored; these can be
adapted as required. With each
acknowledgment of the parameter sets, all
parameters will be reset to the values
listed in the table.

8.4.1 Entry into the default setting

Simultaneously press the UP key
and the DOWN key for 3 sec.
The security prompt appears in
the display
Programming can be exited
again using the ENTER key.
Press the UP key or the DOWN
key to continue with the
programming.
The security prompt YES
appears in the display
Enter the default menu by
pressing the ENTER key
The parameter set last
programmed appears in the
display

8.4.2 Selecting the parameter sets

The parameter sets are selected
using the UP key and the DOWN
key.
Default parameter set 1
Default parameter set 2
Default parameter set 3

8.4.3 Accepting the setting

Pressing the ENTER key accepts
the current setting and returns to
the operating mode.
The text SAVE is shown in the
display for 2 sec.
www.kuebler.com