main counter = zero
Batch counter counts the number
of automatic repetitions of preset
2
Output 1 active when batch
counter > Preset 1
Manual reset sets main counter
to preset value 2 and batch
counter to zero
Electronic reset only sets the
main counter to preset value 2
Count mode ADDING with
automatic reset and Total
counter
Output 2 (timed signal) active
when main counter = preset
value 2
Automatic reset to zero when
main counter = preset value 2
Total counter counts all the count
pulses from the main counter
Output 1 active when total
counter > preset value 1
Manual Reset sets both counters
to zero
Electrical reset sets only the
main counter to zero
Count mode SUBTRACTING
with automatic reset and Total
counter
Output 2 (timed signal) active
when main counter = zero
Automatic reset to preset value 2
when main counter = zero
Total counter counts (sub from
preset value 1) all count pulses
from main counter
Output 1 active when Total
counter < zero
Manual reset sets both counters
to the preset values
Electrical reset sets only main
counter to preset value 2
Tracking Preset mode
When preset 2 is changed then
preset 1 automatically tracks it.
Reset to zero
Preset 1 relative to Preset 2
Tracking Preset mode with
automatic reset
When preset 2 is changed then
preset 1 automatically tracks it.
Reset to zero.
Automatic reset to zero when
www.kuebler.com
main counter = preset value 2.
Preset 1 relative to Preset 2
7.8.5.3 Submenu for configuration
Submenu for matching the input
pulses to the display.
Unit of time
Seconds
Decimal point setting determines
the resolution
Minutes
Decimal point setting determines
the resolution
Hours
Decimal point setting determines
the resolution
Hrs. Min. Sec.
Decimal point setting
(determines the resolution)
0
0.0
0.00
0.000
Set value
Set value can be programmed
from 000000 to 999999
A previously programmed
decimal point will be displayed
7.8.5.4 Submenu for reset mode
Submenu for setting the reset
mode
Reset mode
Manual reset (reset key) and
electrical reset (reset input)
No reset possible
(reset key and reset input
inhibited)
Only manual reset possible
(reset key)
Only manual reset possible
(reset key)
Electrical Reset:
Always resets only the main counter.
Manual Reset:
Resets the main counter (ACTUAL) and
auxiliary counters (BATCH or TOTAL), if the
value of the main counter or the value of an
auxiliary counters is shown on the display.
no decimal place
1 decimal place
2 decimal places
3 decimal places