Kübler CODIX 560 Manual Del Usuario página 37

Contador electrónico de preselección con dos preselecciones
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

When the Lock input is activated,
the setting of the preset values
and the programming are both
inhibited.
7.8.3.2 Submenu for Output operations
Submenu for determining the
operation of the outputs
Output operation
(See also under 18.)
Count mode ADDING
Outputs active when count status
> preset value
Reset to zero
Count mode SUBTRACTING
Output 1 active when
count status < preset value 1
Output 2 active when
count status < 0
Reset to preset 2
Count mode ADDING with
automatic reset
Output 1 active when count
status > preset value 1
Output 2 (timed signal) active
when count status = preset value
2
Automatic reset to zero when
count status = preset value 2
Reset to zero
Count mode SUBTRACTING
with automatic reset
Output 1 active when count
status < preset value 1
Output 2 (timed signal) active
when count status = 0
Automatic reset to preset 2 when
count status = 0
Reset to preset 2
Count mode ADDING with
automatic reset and Batch
counter
Output 2 (timed signal) active
when main counter = preset
value 2
Automatic reset to zero when
main counter = preset 2
Batch counter counts the number
of automatic repetitions of preset
2
Output 1 active when Batch
counter > preset 1
Manual reset sets both counters
to zero.
www.kuebler.com
Electrical reset sets only the
main counter to zero.
Count mode SUBTRACTING
with automatic reset and Batch
counter
Output 2 (timed signal) active
when main counter = zero
Automatic reset to preset 2 when
main counter = zero
Batch counter counts the number
of automatic repetitions of preset
2
Output 1 active when Batch
counter > preset 1
Manual reset sets main counter
to preset value 2 , batch counter
to zero
Electrical reset only sets the
main counter to preset value 2
Count mode ADDING with
automatic reset and Total
counter
Output 2 (timed signal) active
when main counter = preset
value 2
Automatic reset to zero when
main counter = preset value 2
Total counter counts all the count
pulses from the main counter
Output 1 active when total
counter > preset value 1
Manual Reset sets both counters
to zero
Electrical reset sets only the
main counter to zero
Count mode SUBTRACTING
with automatic reset and Total
counter
Output 2 (timed signal) active
when main counter = zero
Automatic reset to preset value 2
when main counter = zero
Total counter counts (sub from
preset value 1) all count pulses
from main counter
Output 1 active when Total
counter < zero
Manual reset sets both counters
to the preset values
Electrical reset sets only main
counter to preset value 2
Tracking Preset mode
When preset 2 is changed then
preset 1 automatically tracks it.
Reset to zero
Preset 1 relative to Preset 2
Tracking Preset mode with
automatic reset
Page 9
Tabla de contenido
loading

Tabla de contenido