ENGLISH
IMPORTANT: The instruction manual you are holding includes essential information on the safety measures to be
implemented for installation and start-up. Therefore, the installer as well as the user must read the instructions before
beginning installation and start-up.
Keep this manual for future reference.
To achieve optimum performance of the LumiPlus Mini light for LED's, follow the instructions provided below:
1. VERIFY THE CONTENTS OF THE PACKING:
The following accessories are included inside the box:
QUICK COUPLING LUMIPLUS MINI LIGHT
Models :
52124, 52125, 52130, 52131,
52136, 52137, 52155 and 52156
LUMIPLUS MINI LIGHT FOR SPAS
Models :
52126, 52127, 52132, 52133,
52138, 52139, 52159 and 52160
2. GENERAL CHARACTERISTICS:
This floodlamp is a Class III electric apparatus with very low safety voltage.
The floodlamp complies with IPX8 degree of protection (resistance to penetration of dust, solid bodies and humidity) at a
nominal immersion depth of 2 m.
This floodlamp complies with international safety standards for lights, especially the EN 60598-2-18 standard: LIGHTS
PART 2: SPECIFIC REQUIREMENTS SECTION 18 LIGHTS FOR SWIMMING POOLS AND SIMILAR APPLICATIONS.
The manufacturer is not responsible in any circumstances for assembly, installation or start-up of any electric components
which have been inserted or handled at locations other than its own premises.
3. INSTALLATION:
• In order to clearly light a pool it is recommended to install a floodlamp every 5 m
which are especially deep, a floodlamp is required for every 10 m
• In order to prevent glare, the floodlamps should be installed so that they face away from the residence or usual view of
the swimming pool.
• In the event that lighting is used in training or competition pools, the floodlamps should be installed on the sides to
prevent glare on the swimmers.
• To avoid the need to empty the pool to change the lamp, we recommend that the floodlamp be installed in areas which
are accessible from the upper edge of the pool.
Prior to installation verify that the gland seal has been fully tightened.
4. ASSEMBLY:
Quick coupling LumiPlus Mini light
This light is manufactured for installation in guiding tube.
1. Install the wall conduit in the concrete wall, at a distance of 400-700 mm. below the water level (Fig. 1).
2. The wall conduit must be extended with a cable conduit the length of which remains above the maximum level of the
swimming pool or spa (Fig. 5).
• Unit floodlamp
• Decorative cover
• O'ring
• Installation and
maintenance manual
• Manual for electrical
connection
• Unit floodlamp
• Decorative cover
• Butt joint
• Nut
• Installation and
maintenance manual
• Manual for electrical
connection
LUMIPLUS SPOT MINI LIGHT (1)
Models :
52128, 52129, 52134, 52135,
52140, 52141, 52157 and 52158
3
of water volume.
2
• Unit floodlamp
• Key for Mini light
• Installation and maintenance
manual
• Manual for electrical connection
(1) These models of projectors
need the niche that is available
separately
2
of water surface. In swimming pools