Super Digital Inverter
7
ELECTRICAL WORK
1. Remove valve cover screw.
2. Pull the valve cover downward to remove it.
Piping cover
Indoor/outdoor
connecting wires
Power wire
EN
Valve cover
The dashed lines show on-site wiring.
Input power
220-240 V~,
•
For the air conditioner, connect a power wire with the
following specifications.
Power supply
Maximum running current
Installation fuse rating
Power wire
Indoor/outdoor connecting
wires
•
•
•
•
17
Wiring between Indoor Unit and Out-
door Unit
(Main circuit)
L
50 Hz
N
Outdoor unit
Earth
Leakage
breaker
Connect the indoor/outdoor connecting wires to the
identical terminal numbers on the terminal block of each
unit.
Incorrect connection may cause a failure.
Model RAV-
CAUTION
Wrong wiring may cause a burn-out of some electrical
parts.
Be sure to use the cord clamps attached to the product.
Do not damage or scratch the conductive core or inner
insulator of the power and inter-connecting wires when
peeling them.
Use the power and Inter-connecting wires with specified
thicknesses, specified types and protective devices
required.
(Indoor/outdoor
connecting wires)
1
1
2
2
Remote
3
3
controller
Indoor unit
SP40, SP45, SP56
220-240 V~, 50 Hz
15 A
16 A (all types can be used)
H07 RN-F or 60245 IEC 66
2
(2.5 mm
or more)
H07 RN-F or 60245 IEC 66
2
(1.5 mm
or more)