It is the responsibility of the installer/owner to ascertain
compliance with specific local regulations prior to installa-
tion. Jacuzzi Europe S.p.A. gives no guarantee in this respect
and declines all responsibility regarding the compliance of
the installation performed.

Technical Features

Power supply (x)
Total consumption
Volt
Hertz
Ampere
220-240 ~ 50/60
26 (k)
(k): at 230 V - (j): absorbed power

User safety

It is important to make sure that personnel tasked to install
or manage the system are qualified as per legal requirements in
effect in the country where installation is carried out.

Electrical preparations

The equipment can also be installed in Countries where
the 220-240V voltage is supplied by a two-phase system. For
the connection please refer to the instruction manual.
Prepare a separate power supply line (220-240 V~: min. 4
mm
2
); this line may be prepared near the main line (or the one
that supplies the hot tub.
Note: The cross-sections of the wires must take account not
only the systems absorption but also the cable path and the
distances, the chosen protection systems and the specific
regulations for fixed electrical systems in force in the coun-
try where the hot tub is installed.
The installer must comply with the above regulations, and also
use watertight connectors at connection points. He must also
guarantee compliance with the specific current standards for
systems in the country in which the hot tub is installed.
It is mandatory to comply with this instruction. Any other
procedure is prohibited.

Electrical safety

Installation must be carried out by qualified and authorized
personnel, in compliance with current national provisions.
It is the responsibility of the installer to select mate-
rials based on their intended use, to carry out work
properly, to check the condition of the system that
the unit will be connected to and that it ensures safe-
ty of use also concerning maintenance work and the
possibility to examine the system.
The electrical system of the building must be provided
with a 0.03A differential switch and with an efficient
kW
6 (j)
protection (earth) circuit. Check for proper operation
of the differential switch by pressing the TEST button,
which should trip.
Parts containing live parts must be inaccessible to a
person in the bath.
If the building's electrical system is not able to guaran-
tee a stabile power supply, it is recommended to install
a voltage stabiliser that suitably dimensioned for the
required power upstream of the equipment.
For connection to the supply network, we advise installing an
isolating multi-pole switch, which will ensure complete discon-
nection in the instance of a category III overvoltage; these de-
vices must be positioned in an area that complies with the safety
regulations.
The installation of electrical devices and equipment (sockets,
switches, etc.) near the hot tub must be in compliance with legal
standards and regulations in the country where the hot tub is
installed.
For the equipotential connection as required by specific nation-
al standards, the installer must use the terminal provided (stand-
ard EN 60335.2.60) and marked with the symbol . In particular,
an equipotential condition must be established for all metallic
masses surrounding the hot tub, for example water and gas pipes,
metallic platforms, and so on.