13 .7 Special functions
Gas test
 Turn the unit OFF using main switch 9.
 Press the torch key and keep it pressed.
 Turn the unit ON using main switch 9.
9 The solenoid valve of the unit will go on
and the gas supply can be tested/adjust-
ed. The function is active for 30 seconds
and will be automatically stopped. Re-
pressing the torch key. can interrupt the
gas test.
Fan test
 Turn the unit ON using main switch 9.
9 The fan will start for function purposes.
Operation panel test
 Press the mode key 60 for at least 5 sec-
onds.
9 All operation displays will flash for approx.
20 seconds.
14
Messages
During operational faults/malfunction , the
7-segment display 47 displays an error
code.
Code Error description
no program
E00
Excessive tempera-
E01
ture
- 50 -
13 .8 Reset setting
 Turn the unit OFF using main switch 9.
 Press the mode key 60 and keep it
 Turn the unit ON using main switch 9.
9 All symbols and displays will light up
Note
Selected programme number does
not exist.
Instead of material thickness „--- "
is displayed and by pressing the
torch key „E00" shows up. Welding
is not possible at activated charac-
teristic line and set welding step.
The equipment has been over-
heated
Master reset
Attention All personal settings
i
will be lost .
All welding and secondary param-
eters are reset to their factory set-
tings.
pressed.
shortly to confirm reset.
As long as there is an error code
i
on display welding is not possible.
Messages
Rectification
Select a different char-
acteristic line
Select a different weld-
ing step
Allow the system to cool
down in standby, check
the ventilation system
10.13