SYMPTOM
PROBABLE CAUSE
JAWS SLIPPING ON MANDRELS Jaws dirty or need lubrication.
Jaws worn.
RIVET FAILS TO INSERT INTO
Incorrect nosepiece.
NOSEPIECE
Shear ring stuck in hole of nosepiece.
RIVET MANDREL DOES NOT
Rivet not fully set.
BREAK
Mandrel break load requirement too high.
Insuffi cient air pressure.
SUCTION NOT WORKING
Tool not connected to air supply.
Collector not tight or missing.
Mandrel path blocked.
LOW VACUUM
Dirty Silencer.
Collector is full of mandrels.
Insuffi cient air pressure.
SPARE PARTS
Y.135FKE
WE, FACOM S.A.S., 6/8 RUE GUSTAVE EIFFEL - BP 99 - 91 423 MORANGIS CEDEX FRANCE, DECLARE UNDER OUR OWN RESPONSIBILITY
THAT THE PRODUCT Y.135F – FACOM PNEUMATIC RIVETER
- IS IN CONFORMITY WITH THE «MACHINERY" DIRECTIVE 98/37/EC ANNEXE I, II, III AND V
- AND IS IN CONFORMITY WITH THE PROVISIONS OF THE HARMONISED EUROPEAN STANDARD EN 792-6
TROUBLESHOOTING
Y.135FKM
CE Declaration of Conformity
REMEDY
Clean and lube jaws.
Replace jaws.
Install correct nosepiece.
Remove shear ring, check for the correct
Nosepiece and review application parameters to
ensure proper riveting.
Repeat stroke required, or change rivet.
Upgrade tool.
Adjust air supply pressure to recommended level.
Connect to recommended air supply source.
Check Collector.
Clear mandrel path.
Clean or change Silencer.
Discard the mandrels.
Adjust air supply pressure.