8.0 - VOLUMETRIC PROPORTIONAL DOSING PUMP
Pump models: PB-F and PB-VFT.
In this series the pump is controlled by pulses emitted from a w.meter reed contact (K). The number of pulses is pro-
portional to the water flow point where the flow meter is installed.
External pulses reach the pump through the w.meter connector (F) and by a specific adjustment will inject into the
pipeline an amount of additive proportional to the liquid that flows into the line.
8.1 - PROPORTIONAL DOSING PUMP
This model can either works with manual or fixed proportional regulation: connected to a pulse emitting water
meter will give an injection for every pulse received.

8.1.1 - ACCESSORIES

• 1 flexible PVC suction hose, transparent crystal type, length 2 m;
• 1 semirigid polyethylene hose, white, length 2 m;
• 1 injection valve 3/8 BSP m;
• 1 filter;
• 1 instructions/operating booklet.
8.1.2 - TYPICAL INSTALLATION (Fig.16)
A Injection valve
B
Power supply
C Filter
D Floating level switch
F
Water meter connector
G Level switch connector
H Cable gland
K
Pulse emitting water meter
I
Chemical tank
S
Process tank
PB-F
Fig. 15
39
PB-F
I
Fig. 16