* When the power supply cord is connected, it must
have a capacity of not less than 4A. The main power
supply must be equipped with an earth leakage circuit
breaker of at least 4A with functions of overload and
short circuit protection.
* The fixed wiring must incorporate a means for
disconnection from the supply having a contact
separation of at least 3 mm in all poles.
[FM-481]
For the U.K. and the Republic of Ireland only
* The wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wire in the mains lead of this
appliance may not correspond with the coloured
markings identifying the terminals in your plug,
proceed as follows:
The wire which is coloured Green-and-Yellow must
be connected to the terminal in the plug which is
marked with the letter E or by the symbol
coloured Green or Green-and-Yellow. The wire which
is coloured Blue must be connected to the terminal
which is marked with the letter N or coloured Black.
The wire which is coloured Brown must be connected
to the terminal which is marked with the letter L or
coloured Red.
* Should the socket outlets in the installation site not
be suitable for the plug supplied with your product,
the plug must be removed (cut off if it is moulded on
plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the power
supply cord, it must be disposed of. There should
be no attempt to reuse it. Inserting such a plug into
a socket elsewhere presents a serious risk of
electrical shock.
* The non-rewirable plug must never be used without a
fuse cover being fitted.
The correct replacement for the detachable fuse
cover is identifiable from the manufacturer's reference
number stamped on the plug.
Supply of replacement fuse covers can be obtained
from Hoshizaki Parts/Service Centres.
Fuses should be rated at 13A and approved to BS
1362.
5. WATER SUPPLY AND DRAIN
CONNECTIONS
(For the U.K. only, the connections must be in
accordance with current requirements of the Model
Water Byelaws 1986 SI No. 1147)
* Only potable water should be used for the icemaker.
* Water supply pressure should be minimum 0.5 bar
and maximum 8 bar. If the pressure exceeds 8 bar,
use a proper pressure reducing valve. Do NOT
throttle back the supply tap.
* A plumbing permit and services of a licensed plumber
may be required in some areas.
* The icemaker drain is gravity flow, so ensure drain
pipe has an adequate pitch or fall.
* Water should drain into an open trap.
1) Attach angled end of white flexible inlet hose
or
(accessory) to the G3/4 fitting on the rear of the
icemaker as indicated, ensuring rubber sealing
washer is correctly positioned. Hand tighten
sufficiently to provide leak free joint.
2) Attach the other end of inlet hose(s) to the water
tap, noting washer(s) is/are correctly positioned
before hand tightening as above.
Inlet Hose
Outlet Hose
4
Water Supply
Inlet G3/4
Drain Outlet
R3/4
Fig. 7