ENGLISH
2. LOCATION
IMPORTANT
1. This icemaker is not intended for outdoor use.
Normal operating ambient temperature should
be within 5°C to 40°C. Normal operating water
temperature should be within 5°C to 35°C.
Operation of the icemaker, for extended
periods, outside of these normal temperature
ranges may affect production capacity.
2. The installation and operating performance of
the compressor system should be in
a c c o r d a n c e w i t h t h e r e s p e c t i v e
manufacturer's guidelines and are beyond the
control of Hoshizaki.
3. The icemaker should not be located next to
ovens, grills or other high heat producing
equipment.
4. The location should provide a firm and level
foundation for the equipment.
5. Allow 15 cm clearance at rear and sides for
proper air circulation and ease of maintenance
and/or service should they be required. Allow
60 cm clearance on top to allow for removal
of the Auger.
6. This appliance is not suitable for installation
in an area where a water jet could be used
and where dripping is not allowed.
7. Do not place anything on top of the icemaker
or in front of the Louver.
3. INSTALLATION
* Incorrect installation can cause harm to people,
animals or things, for which the manufacturer cannot
be held responsible.
1) Fully screw in the four legs provided (bin accessory)
into the Storage Bin underside. See Fig. 3.
Bottom Plate
Adjustable Legs
2) Position the Storage Bin in the selected permanent
site.
3) Place the icemaker on top of the Storage Bin by
holding the bottom.
4) Secure the icemaker to the Storage Bin, by using
the two mounting brackets and two bolts provided.
See Fig. 4.
Bolt
5) Seal the seam between the icemaker and the
Storage Bin with food grade sealant.
6) Adjust the four legs on the bottom (adjustable from
0 to 25.4 mm) to have the icemaker perfectly
horizontal. Use the spirit level. See Fig. 5.
7) The icemaker must be connected to the liquid and
suction lines of the compressor system using two
copper tubes of sufficient sizes directed to the
rear of the icemaker for connection to the pre-fitted
internal copper tubes. Both tubes should be
insulated separately.
Note: 1. The sizes of the interconnecting pipes
Fig. 3
2
Icemaker
Bin
Mounting
Bracket
Adjust legs
between the icemaker and the compressor
system should be 1/4" OD for the liquid line
and 1/2" for the suction line up to a maximum
of 20 m (assuming a straight run). For each
90° bend, add an equivalent 0.5 m to the
overall pipe length (E.g. 20 m straight pipe
+ four 90° bends = equivalent 22 m of straight
Fig. 4
Fig. 5