PROBLEM
EN
The fire extinguish
and the stove
stops
Stove running
and display
showing "BURN
POT CLEANING"
Flames are weak
and orange
coloured, pellets
do not burn
properly and the
glass blackens
The exchanger
fan continues to
turn even though
the stove has just
cooled
Ash remains
along the stove
86
CAUSE
SOLUTION
Empty hopper
Full the hopper.
Auger blocked
by a foreign
Clean the auger.
object (for
example nails)
Bad quality
Try other types of pellets.
pellets
Pellet drop value
too low "phase
Adjust the pellet loading.
1"
Check if on the
display there
Have the stove checked.
is an "ACTIVE
ALARM"
Automatica
The stove is at minimum, fume fan at maximum. NO
burning pot
PROBLEM!
cleaning
Check as following: probable obstructions of the
Not sufficient
combustible air inlet from the back or from the bottom
combustion air
of the stove; burning pot obstructed holes with too ash
remains. Have the fan blades and auger cleaned.
The exhaust chimney is partially or totally obsturcted.
Obstructed
Contact an expert stove-repairer who checks the
exhaust
stove from the exhaust up to the chimney pot. Provide
immediately for stove cleaning.
Obstructed stove
Provide immediately at the inner cleaning of the stove.
The pellets can burn also thanks to chimney flue
The fume fan is
depression without the aid of the fume fan. Have the
fume fan immediately replaced. it can be noxious to
out of order
health to let the stove running without fume fan.
Faulty fume
temperature
Replace the fume probe.
probe
Faulty mother
Replace the mother board.
board
Faulty or out
of order door
Replace the gaskets.
gaskets
Contact an expert stove-repairer who will immediately
provide for sealing the junctions with high-temperature
Not sealed fume
silicone and/or for replacing pipes with those in
pipes
compliance to current regulations. a not sealed fume
channelisation can be noxious to health.
INTERVENTION
RONDÓ - MIKA