of conformity of the system and will assume the whole responsibility on the final installation and on the
resulting good running of the product.
• As equipment with the stove there is a testing and maintenance manual which must be periodically
executed by the installer.
• Check if there is the combustible air inlet.
• Check the probable presence of other stoves or appliances which could depress the room (see
EXTERNAL AIR INLET page 56).
EN
• Check at switched on stove if there is the presence of CO in the room.
• Check if the chimney has the necessary draught.
• Check if during the fume passage all has been executed in safety (probable fume losses and distances
from flammable materials, etc....).
• The installation of the appliance must enable an easy access for appliance, fume exhaust pipes and
chimney flue cleaning.
• The installation must enable en easy access to the electric connection plug (see ELECTRIC CONNECTION
page 63).
• It is forbidden to install the stove in bedrooms, bathrooms and in rooms used for storing combustible
materials and in one-room flats.
• The installation in one-room flats is allowed if they are in sealed chamber.
• In any case the stove must not be installed in rooms where it can get in touch with water or water
splashes because this can cause burn hazards and short-circuit.
• To install more appliances, the external air inlet must be correctly dimensioned (see EXTERNAL AIR INLET
page 56).