Start up
Check the mains cable regularly for
damage such as aging or formation of
cracks. If you find a damage, then the
cable must be replaced before using it
any further.
Check appliance for damage, have
damages repaired by customer service.
Power connection
For connection values, see technical
–
data and type plate.
The electrical connections must be
–
done by an electrician according to IEC
60364-1.
Danger
Risk of electric shock.
Do not drive over the mains cable.
–
Danger
Risk of injury.
Never wrap the mains cable around
–
your body or your neck.
Do not let the mains cable come in con-
–
tact with the rotating brushes or rotating
pads.
Attach the brush/pad
Disconnect the mains plug from the
socket.
Loosen the clamps of the level adjust-
ment.
Swivel the tension lever to the front into
a horizontal position.
Tighten the clamps of the level adjust-
ment.
Tilt the appliance rearward.
Place the disc brush/driver plate onto
the actuator and turn in anti-clockwise
direction.
Fill the detergent tank (option)
Warning
Risk of damage. Only use the recommend-
ed detergents. With respect to different de-
tergents the operator bears the increased
risk regarding the operational safety and
danger of accident. Only use detergents
that are free from solvents, hydrochloric
acid and hydrofluoric acid.
Follow the safety instructions for using de-
tergents.
Fill detergent solution into the detergent
tank.
Warning
Risk of injury! The operation of the appli-
ance requires practice.
Ensure that there are no obstacles in
–
the area to be cleaned.
Check the floor consistency for its suit-
–
ability.
The handling becomes more difficult
–
with uneven or rough surfaces.
Warning
Risk of accident due to loss of control over
the appliance. Do not adjust the handle un-
less the motor is at a standstill.
Loosen the clamps of the level adjust-
ment.
Tilt the handle into a comfortable posi-
tion (arms outstretched).
Tighten the clamps of the level adjust-
ment.
– 3
EN
Operation
Adjust handle
5