Putting Into Operation - Abicor Binzel ABIDRIVE V2 Instructivo De Servicio

Alimentador de alambre en frío tig
Ocultar thumbs Ver también para ABIDRIVE V2:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TIG cold-wire feeder
The wire spool seat with a brake is used to hold standardised welding wire spools with a maximum weight
of 16 kg and a maximum diameter of 300 mm.
NOTICE
• Restrictions for aluminium: Max. length of the cable assembly: 6 m
• Restrictions for unalloyed/low-alloy steels: Max. length of the cable assembly: 6 m

6 Putting into operation

Personal injuries and material damage
Incorrect connection of the power source can result in personal injuries and material damage.
• Connect the ABIDRIVE only to properly earthed power sockets.
• Operate the ABIDRIVE only with an intact connection lead with a protective conductor and safety
• Depending on the power source, a special intermediate cable assembly is required for operation.
• Only use ABICOR BINZEL cable assemblies.
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout all maintenance, servicing, assembly,
disassembly and repair work:
• The entire system must be disconnected from the power supply prior to performing any work on it.
• Close the compressed air supply.
• Close the gas supply.
• Disconnect the mains plug.
Risk of crushing
Hands can be pulled in and crushed by moving wheels.
• Do not reach into moving wheels.
NOTICE
• Please take note of the following instructions:
• The system may only be installed and put into operation by qualified personnel (in Germany see
• The device must only be used in environments with sufficient ventilation.
DANGER
plug.
DANGER
WARNING
 3 Product description on page EN-5
TRBS 1203).
6 Putting into operation
EN - 9