Installation - Honeywell W8835 EnviraZone Manual De Instrucciones

Ocultar thumbs Ver también para W8835 EnviraZone:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

W8835 ENVIRAZONE PANEL
Accessory
40 VA transformers
High and low limit sensor
Round static pressure regulator damper
Rectangular static pressure regulator damper
a
Supplied in the Y8835 kits.

INSTALLATION

Mounting
CAUTION
Equipment Damage Hazard.
Do not mount W8835 inside HVAC equipment.
Mount only on wall or on cold air return.
1. Mount the thermostats in each zone of the living space
using the installation instructions provided with each
thermostat.
2. Mount the dampers in the ductwork using the installation
instructions provided with each damper.
3. Mount the W8835 EnviraZone Panel near the HVAC
equipment; locate it on a wall or on the cold-air return.
See Fig. 2.
4. Level the W8835 for appearance only.
68-0258—04
Table 2. Required Accessories (Not Supplied with Panel).
Description
AT140A1042
C7835A1009
SPRD7
SPRD8
SPRD9
SPRD10
SPRD12
SPRD14
SPRD16
SPRD12x8
SPRD12x10
SPRD12x12
SPRD20x8
SPRD20x10
SPRD20x12
4
a
a
300
400
600
750
1200
1800
2400
1000
1200
1400
1600
2000
3000
RETURN
AIR
W8835
AIR CLEANER
Fig. 2. W8835 mounting location.
Wiring
CAUTION
Voltage Hazard.
Can cause electrical shock or equipment damage.
Disconnect power before continuing installation.
Wiring must comply with applicable codes, ordinances,
and regulations.
Bypass Rating
(cfm)
FURNACE
W8835
M31121