Specifications - Master MH-80V-LPC-A Manual Del Usuario E Instrucciones De Operación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

– ALWAYS install the heater so that it is not directly
exposed to water spray, rain, dripping water, or
wind.
– Use heater in accordance with all local codes.
In the absence of local codes, refer to The
National Fuel Code, NFPA 54/ANSI Z223.1.
For use with propane (LP)
WARNING
gas only.
– This heater is shipped from the factory
for use with propane (LP) gas only. Do not
convert to any other gas. Installation must
conform to local codes, or in their absence,
with the standard for the Storage and Handling
of Liquefied Petroleum Gases NFPA 58 and
the Natural Gas and Propane Installation Code
CSA B149.1.
– Gas supply connections should be checked by
using a 50/50 soap and water solution. Never
use a flame to check for gas leaks.
RISK OF FIRE! ALWAYS LOCATE HEATER ON A STABLE AND LEVEL SURFACE!
WARNING
(SEE FIGURE 1)
Figure 1
Model #
BTU
Fuel Consumption (Lbs./hr)
Heat Settings
Maximum Operating Hours
Required Cylinder Lbs.
Fuel Type
Heating Area (Ft.
)
2
© 2018 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING,
CONNECTED TO A POWER SOURCE, OR WHILE
CONNECTED TO A FUEL SOURCE
SAFETY INFORMATION (CONT.)

SPECIFICATIONS

MH-80V-LPC-A
60,000 / 70,000 / 80,000
2.8 / 3.2 / 3.7
3
36
100
Propane
1,800
Specifications subject to change without notice.
The hose assembly shall be
WARNING
pro tected from traffic, building
material and contact with hot surfaces both
during use and while in storage.
– Locate LP cylinder at least 6 feet (10 ft. in
Canada) from the heater, and do not direct
heater discharge towards the LP cylinder
unless it is at least 20 feet from the heater.
– Use only the regulator and hose assembly
provided with this heater. Inspect the
regulator/hose assembly prior to each use of
the heater. If there is excessive abrasion or
wear, or if the hose is cut, replace it with the
proper assembly shown in the parts list, prior
to using the heater.
Minimum and Maximum Inlet Pressure
MH-80V-LPC-A
Min.
Max.
X
4
Convection Heater User's Manual
MH-200V-LPC-A
5 PSI
Bottle Pressure
MH-200V-LPC-A
70,000 – 200,000
3.2 / 9.3
Variable
31
100
Propane
5,000
Tabla de contenido
loading

Este manual también es adecuado para:

Mh-200v-lpc-a

Tabla de contenido