Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

CONSUMER: READ AND RETAIN THESE INSTRUCTIONS FOR FUTURE USE
Locating Your Serial Number:
Your serial number can be found on the heater's rating label. It will be 8 digits. For Example: 12345678.
Have your Serial Number ready before calling customer service at 1-800-641-6996.
DANGER
SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE,
EXPLOSION, BURN. ASPHYXIATION, CARBON MONOXIDE POISONING AND / OR ELECTRIC
SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE
OR SERVICE THIS HEATER. IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS
AN INSTRUCTIONS MANUAL, LABEL, ETC. CONTACT THE MANUFACTURER.
WARNING
PER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER
AS RECOMMENDED BY THESE INSTRUCTIONS. NEVER USE THE
HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR
AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE,
SOLVENTS, PAINT THINNERS, DUST PARTICLES OR UNKNOWN
CHEMICALS.
This heater is designed and approved for use as a construction heater in accordance with
Standard for Gas fired Construction heaters ANS Z83.7 * CSA 2.14-2017. CHECK WITH YOUR
LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE ANY QUESTIONS ABOUT APPLICATIONS.
Other standards govern the use of fuel gasses and heating products for specific uses. Your
local authority can advise you about these.
MODEL NUMBER
MH-18-PNCH-A
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUC-
TIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH,
FIRE, BURN, INHALATION, AND EXPLO-
SION HAZARD. KEEP SOLID COMBUSTI-
BLES, SUCH AS BUILDING MATERIALS, PA-
Fax: 320-251-2922 • Web:
CABINET HEATER
User's Manual &
Operating Instructions
Sauk Rapids, MN 56379 USA • Toll Free
www.masterindustrialproducts.com
© 2019 Pinnacle Climate Technologies, Inc.
Factory ID: 525
(800) 641-6996
MACC-404
loading

Resumen de contenidos para Master MH-18-PNCH-A

  • Página 1 User’s Manual & Operating Instructions MODEL NUMBER MH-18-PNCH-A CONSUMER: READ AND RETAIN THESE INSTRUCTIONS FOR FUTURE USE Locating Your Serial Number: Your serial number can be found on the heater’s rating label. It will be 8 digits. For Example: 12345678.
  • Página 2 NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE. TABLE OF CONTENTS Safety Information............2-5 Ventilation................10 Specifications..............5 Storage and Maintenance...........11 Features................6 Troubleshooting Guide..........12 What’s in the Box............6 Exploded View & Parts List.........13 Unpacking................6 Warranty................14 Assembly................7...
  • Página 3 NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE. SAFETY INFORMATION (CONT.) RISK OF INDOOR PROPANE IS AN WARNING DANGER AIR POLLUTION! EXPLOSIVE GAS. The products described in this manual are pro- ANSI A10.10, ANSI Z223.1/NFPA 54 Liquefied pane direct-fired, forced air heaters.
  • Página 4 NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE. SAFETY INFORMATION (CONT.) CAUTION! HOT WHILE WARNING WARNING AIR QUALITY HAZARD IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, ANIMALS, CLOTHING AND COMBUSTIBLES AWAY FROM HEATER.
  • Página 5 – This heater is shipped from the factory for use Minimum and Maximum Inlet Pressure with propane (LP) gas only. Do not convert Model MH-18-PNCH-A to any other gas. Installation must conform Min. 5 PSI to local codes, or in their absence, with the Max.
  • Página 6 NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE. WHAT'S IN THE BOX Hose and Regulator Heater Cabinet FEATURES Piezo Valve Knob Handle Slot Protective Guard Safety Guard Rear Castor Front Castor UNPACKING 1.
  • Página 7 NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE. ASSEMBLY 1. Place heater on a flat surface. Connecting to Gas Supply 2. Fold propane tank tray down (see Figure 1) IMPORTANT! - Always use a propane (LP) 3.
  • Página 8 NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE. OPERATION – Never connect an unregulated LP cylinder to a Propane Supply / Information: construction heater. Propane (LP) – DO NOT subject LP cylinder to excessive heat. This heater is not supplied with a propane cylinder.
  • Página 9 NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE. OPERATION (CONT.) Checking For Leaks Lighting Instructions: 1. STOP! Read all of the safety information – To check for leaks, make up a 50/50 solution provided with this heater.
  • Página 10 Minimum Ventilation Opening Needed – ALWAYS provide a fresh air opening in the heated space of at least 3 square feet (2,800 MH-18-PNCH-A sq. cm) for each 100,000 BTU / Hr. of heater 0.54 ft. output. Provide a larger opening if more heaters are being used.
  • Página 11 NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE. STORAGE / MAINTENANCE Always disconnect the LP cylinder from the regu- Be sure to inspect the heater before each use to lator assembly and remove the LP cylinder from look for any such obstructions.
  • Página 12 NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE. TROUBLESHOOTING GUIDE Problem Possible Cause Solution 1. Air in gas line 1. Keep depressing the gas control knob for at least 30 seconds to remove any in line.
  • Página 13 20341 ODS 3rd Setting Copper 22 Anti Tilt Base Seal Ring Pipe System 23 Anti Tilt PARTS LIST Item # Description MH-18-PNCH-A Front Caster 50-011-0300 Rear Caster 50-011-0305 Piezo Button 50-014-0100 Protective Guard 50-012-0260 © 2019 Pinnacle Climate Technologies, Inc.
  • Página 14 NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE. LIMITED WARRANTY Pinnacle Climate Technologies, Inc. warrants this heater to If Pinnacle Climate Technologies, Inc. finds the item to the original retail purchaser only, to be free from defects in be in normal operating condition, or not defective the item material and workmanship for a period of one (1) year from will be returned freight collect.
  • Página 15 Sauk Rapids, MN 56379 USA • Toll Free (800) 641-6996 Fax: 320-251-2922 • Web: www.masterindustrialproducts.com • Email: [email protected] © 2019 Pinnacle Climate Technologies, Inc.
  • Página 16 CALENTADOR GABINETE Manual del usuario e Instrucciones de operación MODELO N.° MH-18-PNCH-A CONSUMIDOR: LEA Y GUARDE ESTAS INSTRUCCIONES PARA USARLAS EN EL FUTURO Cómo localizar su número de serie: Puede encontrar su número de serie en la etiqueta de valores nominales de su calentador. Tendrá 8 dígitos. Por ejemplo: 12345678.
  • Página 17 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN O A UNA FUENTE DE COMBUSTIBLE ÍNDICE Información de seguridad ........ 2-5 Ventilación ............10 Especificaciones ..........5 Almacenamiento y mantenimiento ....11 Características............
  • Página 18 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN O A UNA FUENTE DE COMBUSTIBLE INFORMACIÓN DE SEGURIDAD (CONTINÚA) PELIGRO ADVERTENCIA EL PROPANO ES UN GAS EXPLOSIVO. de instalación de gas natural y propano CAN B149.1, según ¡RIESGO DE CONTAMINACIÓN DEL AIRE INTERIOR! corresponda.
  • Página 19 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN O A UNA FUENTE DE COMBUSTIBLE INFORMACIÓN DE SEGURIDAD (CONTINÚA) ¡PRECAUCIÓN! CALIENTE MIENTRAS ESTÉ EN FUNCIONAMIENTO. ADVERTENCIA NO LO TOQUE. MANTENGA A NIÑOS, ANIMALES, ROPA Y COMBUSTIBLES LEJOS DEL CALENTADOR.
  • Página 20 La instalación debe cumplir con Presión de entrada mínima y máxima los códigos locales o, a falta de ellos, con la norma Modelo MH-18-PNCH-A para el almacenamiento y la manipulación de gases licuados de petróleo ANSI/NFPA 58 y el Código de Mín.
  • Página 21 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN O A UNA FUENTE DE COMBUSTIBLE QUÉ HAY EN LA CAJA Manguera y regulador Gabinete del calentador CARACTERÍSTICAS Perilla de la Piezo válvula Ranura para el asa Protección...
  • Página 22 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN O A UNA FUENTE DE COMBUSTIBLE ARMADO Coloque el calentador sobre una superficie plana. Conexión al suministro de gas 2. Doble hacia abajo la bandeja del tanque de propano ¡IMPORTANTE! - Use siempre un tanque de gas (vea la Figura 1) propano (LP) que tenga un dispositivo de conexión...
  • Página 23 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN O A UNA FUENTE DE COMBUSTIBLE FUNCIONAMIENTO Nunca conecte un tanque de LP no regulado en un – Suministro de propano/información: Propano (LP) calentador para construcción.
  • Página 24 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN O A UNA FUENTE DE COMBUSTIBLE FUNCIONAMIENTO (CONTINÚA) Inspección de fugas Instrucciones de encendido: ¡ALTO! Lea toda la información de seguridad que Para verificar si hay fugas, prepare una solución –...
  • Página 25 Abertura de ventilación mínima necesaria SIEMPRE provea una abertura para aire fresco en – MH-18-PNCH-A el espacio que caliente de por lo menos 3 pies cuadrados (0.28 m ) por cada 100,000 BTU / h 0.54 pies (29 kWh) de emisión del calentador.
  • Página 26 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN O A UNA FUENTE DE COMBUSTIBLE ALMACENAMIENTO / MANTENIMIENTO Siempre desconecte el tanque de LP del conjunto Asegúrese de inspeccionar el calentador antes de cada del regulador y retire el tanque de LP del calentador uso para buscar cualquier obstrucción.
  • Página 27 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN O A UNA FUENTE DE COMBUSTIBLE GUÍA PARA LA SOLUCIÓN DE PROBLEMAS Problema Posible causa Solución Aire en la tubería de gas. Mantenga presionada la perilla de control de gas por lo menos 30 segundos para eliminar cualquier aire en la línea.
  • Página 28 ODS 20341 Rueda con freno Sistema de tubería de 30 Protección Anillo de sello cobre del tercer ajuste 22 Base antivuelco LISTA DE PIEZAS Pieza # Descripción MH-18-PNCH-A Rueda Delantera 50-011-0300 Rueda Trasera 50-011-0305 Botón del Piezoeléctrico 50-014-0100 Protección 50-012-0260 ©...
  • Página 29 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN O A UNA FUENTE DE COMBUSTIBLE GARANTÍA LIMITADA Pinnacle Climate Technologies, Inc. garantiza este calentador Si Pinnacle Climate Technologies, Inc. descubre que el únicamente al comprador minorista original, como libre de artículo está...
  • Página 30 Sauk Rapids, MN 56379, EE. UU. • Llamada sin costo (800) 641-6996 Fax: 320-251-2922 • Sitio web: www.masterindustrialproducts.com • Correo electrónico: [email protected] © 2019 Pinnacle Climate Technologies, Inc.