H.Koenig AXO900 Manual De Utilización página 7

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
Cleaning of front filter for motor:
Warning: please make sure the power supply of the cleaner has been cut off before carrying out
the following steps:
1. Pull out the power cord plug of the cleaner from the power socket.
2. Press down the handle of the dust barrel to remove the dust barrel, and remove the cover of
the front filter for motor, and then use the brush to clean the filter (sponge and filter gauze with
composite coating) or place it under the cock to clean, as is shown in Figure (8/9).
Figure (8)
Caution:
It is normal that the white central filter in the dust barrel may change color, which cannot affect its
filtration performance. If the hose and the central filter are difficult to clean, we recommend that
you use water to flush them; however, please be sure to place them in the dry air for at least 24
hours after they are flushed by water.
Key Points:
Please note: when the dust collecting barrel or the filter cover is not installed in place, the
operation status will be invalid, and the cleaner will have no dust absorption capacity. At this time,
you need to check carefully whether the dust collecting barrel and the filter cover have been
installed in place.
Caution: please keep the suction passage unobstructed, otherwise the motor may become
overheating or even be damaged.
Replacement of rear filter for motor
The rear filter for motor is installed behind the air outlet grid, which can be washed due to the
materials used. When the surface is jammed seriously by dust, the filter should be replaced by a
new one or washed by water to maintain enough suction force. (Figure 10/11)
Figure (9)
Figure (7)
Tabla de contenido
loading