Useful Tips - Sammic DS-12 Instrucciones

Descalcificador automatico
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
8.
Slowly open the water inlet and outlet taps (fig. 3, B, D)
9.
Reconnect the power supply
10.
If you press simultaneously the
immediately start operating. The screen will now display the time again.

USEFUL TIPS

Through experience, we know that, very often, the cause of malfunctioning water softeners is due
to an incorrect installation of the drainage pipe (fig. 4, A). We therefore recommend that it is
installed correctly (fig. 3, F) and that the pipe supplied in the box is used. Whenever possible, the
installation of a filter before installing the water softener is recommended to eliminate substances
that could compromise the correct operation of the machine.
PROBLEMS A ND SOLUTIONS
THE VALVE DOES NOT AUTOMATICALLY REGENERATE
- check that the electrical power supply is connected (fig. 6, G)
- verify the programming (consult "9 Programming the timer")
THE VALVE REGENERATES AT THE WRONG TIME
- verify the programming of the current time and of the regeneration time.
(consult "9 Programming the timer")
THE BRINE DOES NOT SUCK WATER
- check that the network pressure is at least 2 bar
- check that the drainage pipe is not obstructed and that excessively narrow connectors
which could compress the pipe are not used (fig. 4, A)
- clean the injector (fig. 6, B) (consult "14 Maintenance")
- check that the valve does not suck in air where the speed connections are located (fig. 6, A)
THE BRINE IS FILLED EXCESSIVELY
- check that the drainage pipe is not obstructed and that excessively narrow connectors
which could compress the pipe are not used (fig. 4, A)
- check that the valve does not suck in air where the speed connections are located (fig. 6, A)
- clean the injector (fig. 6, B) (consult "14 Maintenance")
- check that the operating pressure is at least 2 bar
- check that the "salt amount" value is "L" (consult "9.6 Dosage of salt for the regeneration")
THE WATER SOFTENER CONSUMES MORE OR LESS SALT THAN PLANNED
- check that the "salt amount" value is "L" (consult "9.6 Dosage of salt for the regeneration")
- verify the programming of the valve (consult "9 Programming the timer")
(consult "9.5 Selecting the regeneration date")
AFTER THE REGENERATION, THE WATER IS NOT SOFTENED
- check the electrical power supply and the programming of the valve
- check for the presence of salt in the brine (fig. 7)
- check that the mixer screws are properly screwed (fig. 2, B)
Err1 The program has stopped working
Press the
button to restart. If the error persists, the control must be replaced
20
EN
and
buttons for five seconds, the valve will
Tabla de contenido
loading

Este manual también es adecuado para:

Ds-26

Tabla de contenido