Vertical mounting position − preparation
Calculate the required test pressure P
S
+ 10bar *
P
A
DNCKE−...
Piston area A for extending direction
Piston area A for retracting direction
Fig. 30
Case 2: Vertical mounting position test with
additional weight force suspended
1. Place the piston rod in the retracted end
position.
2. Vent the port 2. The clamp is active.
3. Pressurise the cylinder in extending direc
tion at the test pressure P
with piston area A for extending direction
per Fig. 30).
Case 3: Vertical mounting position test with
additional weight force upright
1. Place the piston rod in the advanced end
position.
2. Vent the port 2. The clamp is active.
3. Pressurise the cylinder in retracting direc
tion at the test pressure P
with piston area A for retracting direction
per Fig. 30).
46
m
g
10
A
(calculation
A
(calculation
A
as follows:
A
m = effective load [kg]
g = acceleration due to gravity [9.81 m/s
A = effective piston area [mm
40−...
63−...
2
1257 mm
3117 mm
2
1055 mm
2803 mm
P
Fig. 31
Fig. 32
Festo DNCKE−...−S / KEC−...−S 1002a English
2
]
2
]
100−...
2
2
7854 mm
2
2
7363 mm
A
m
m
P
A