swissflex uni 08 75K Modo De Empleo página 12

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
damage to electronic parts or personal injury. Ensure
that the different comfort zones of the slat base are not
blocked, as this can cause overheating and damage to
the motors.
Do not place heavy objects on the cable to prevent da-
mage. In case of damage to the cable or accessories,
disconnect the mains cable (8) from the power outlet
and have them checked by your Swissflex stockist.
Clean the uni 08_75K and accessories with a dry cloth
only. Do not use detergents or chemical substances.
For safety reasons, change the batteries in the uni
08_75K motor housing every 3 years to prevent leaka-
ges. Swissflex recommends the use of leak-proof 9
V block batteries. In case of contact with the battery
fluid, wash the affected area with plenty of water and
seek medical assistance. Batteries must be disposed
of through a specialist retailer.
Changing the batteries in the motor housing
Carefully remove the battery from the battery clips.
Place two 9 V block batteries into the compartment,
paying attention to the +/- markings. The battery in
the motor housing provides power in case of a power
failure.
Behaviour in case of malfunc-
tions
In case of malfunctions with your uni 08_75K, consult
the following troubleshooting tips. If the problem can-
not be resolved, disconnect the uni 08_75K from the
power outlet and contact your Swissflex stockist.
Problem
Possible cause
Remote control or
No mains supply.
control system not
Manual switch or control system defective.
working.
Control systems
Thermoswitch on the transformer may
suddenly no
have been triggered or may be defective.
longer travel /
Thermal cut-out in the transformer may
move.
have been triggered or may be defective.
Internal fuse may have been triggered or
may be defective.
No mains supply.
Supply line (mains and / or manual switch
/ auxiliary control system) interrupted.
The battery-
Block battery / block batteries flat.
operated electric
reset function
Block battery / batteries not connected.
cannot be acti-
vated.
12
Operating instructions
The uni 08_75K does not work despite being swit-
ched on and all components being connected pro-
perly
Disconnect the mains cable (8) from the power outlet.
Wait a minute and then reconnect it. If necessary, use
a bedside lamp to check that mains voltage (110–240
V) is present. If no voltage is present, check the fuse.
As the remote control of the uni 08_75K is equipped
with micro-processors, irregulatities in power supply
can lead to complications.
After a power failure
Before resuming use of the uni 08_75K, press and
hold the button (6), until all sleep areas have reached
the horizontal position and the motors have stopped
moving.
Activating the emergency set-down
Press the «All motors down» button (6) on the cable
remote control to reach the horizontal (basic) position.
The repeated use of the emergency set-down function
puts a lot of strain on the batteries so that they must
be replaced.
Technical data
Supply voltage: 230–240 Volt / 50-60 Hz
Thrust motors: 6000 N
Supply emergency set-down function:
1x 9 V block battery
Total connected load: 140 W / 6A
Temperature range: + 5 °C to + 40 °C
Solution
Restore mains connection.
Contact your supplier / stockist.
Leave the control system in the rest position for 20-30
minutes.
Contact your supplier / stockist.
Contact your supplier / stockist.
Restore mains connection.
Check the supply line and restore contact if applicable.
Check and replace the block battery / block batteries if
necessary.
Connect the block battery / block batteries.
EN
Tabla de contenido
loading

Tabla de contenido