EN
3.0
RS-232 INTERFACE
The CBC and CBC-M Series of scales can be ordered with a bi-directional RS-232 interface. The scale when
connected to a printer or computer through the RS-232 interface, outputs the weight with the selected
weighing unit.
Specifications:
RS-232 output of weighing data
ASCII code
Adjustable Baud rate: 600, 1200, 2400, 4800, 9600 and 19200 baud
8 data bits
No Parity
Connector:
9 pin d-subminiature socket
Pin 3 Output
Pin 2 Input
Pin 5 Signal Ground
4.0
PARAMETERS
For CBC-M scales, it is necessary to enter a secure menu using a password to set some parameters. The
parameters for the RS-232 interface, real time clock and the accumulation function can be set by the user.
Please see details in the complete manual.
4.1
AUTO SLEEP FUNCTION
This function may be enabled or disabled by the user. If enabled, when the scale is not used for some time
(as pre-set by the user under this function) it automatically switches off. To set this parameter-
During self-checking, press [Zero] and release at once. The display shows
key to scroll through the auto sleep values.
"0" Auto sleep mode disabled
"1" Auto sleep after 1 minute
"5" Auto sleep after 5 minutes
"10" Auto sleep after 10 minutes
Press [Tare] to set the value. The scale returns to zero.
© Adam Equipment Company 2013
5
3026610534, Revision A3, July 2013
"SLEEP nodE"
. Press [U. Wt./Units]