Fitting the valves
Please note
Please note the following when fitting valves onto the
basis blocks:
S Use only uniform valve functions. Valves with the
function in basic position closed" may not be com
bined with valves in basic position open".
S Use only valves of the same voltage type.
S Basis blocks type MHP...: Fit only semi inline valves.
S Use the following cover plate for sealing a non−as
signed valve location:
type MHA1−BP3−PI
S Protect also the electrical connections against dirt
with the adhesive foil supplied with the cover plate.
2
1
1
Valve
2
Tightening torque for valve/
cover plate 0.2 Nm − 20 %
0603a
Festo MH1..−PCB
3
4
5
English
Adhesive foil
Cover plate
Basis block
2
3
4
5
23