1I. Connection
Have your plug checked (presence of fuses, amps and
30 mA circuit breaker) by a qualified electrician.
III. Description
A
- P button: allows access to compartment temperature settings and to control unit setting.
B
- U button: allows you to power up the appliance and place it on standby
C/D
- allows you to change the temperature values of each compartment.
E
- cold function indicator (if on= the left-hand compartment is chilling the wine)
F
- cold function indicator (if on= the right-hand compartment is chilling the wine)
G
- warm function indicator (if on= the right-hand compartment is warming the wine)
IV. Temperature setting
The Wine Bar 8.0 appliance allows you to bring wine to the correct serving temperature and protect open bottles from oxidation.
1
1
Press the
key. the message
can now set the temperature of the left-hand compartment.
2
To change this setting, press the
it or the
key to lower it. The
setting range is 6°C - 15°C / 43°F - 59°F.
3
Once you have obtained the desired value, confirm it
by pressing the
key. The message
appear. You can now set the temperature of the right-hand
compartment.
Stand-by
Alarm
E
2
2
"SP1"
will appear. You
key to increase
"SP1"
temperature
''SP2''
will then
G
B
C
D
F
A
3
OK
4
To change the value, press the
or the
key to lower it.
''SP2''
The
temperature setting range is 9°C - 18°C /
48°F - 64°F.
5
Confirm by pressing the
and return to the normal display.
4
5
OK
4
key to increase it
key to save the changes