Promax PROWATCH TELMO Manual De Instrucciones página 50

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Active: Turn ON or Turn OFF the monitoring channel.
Frequency: Select the frequency of the channel that will be monitored.
Alarm Power or Warning Power: Set the power threshold which the
ProWatch light up the leds and commute the relays. First of all it shows the
warning Leds. If the power continues going down the Alarm will be showed.
The range is between — 107 dBm and — 20 dBm .
General Configuration: ProWatch could edit a common configuration for all
the channels, and it could check the thresholds levels of MER and VBER. For
that reason the Alarms or Warnings of each channel will light up and the relay
commute when these limits are exceeded. The MER level could be fixed
between 18 dB and 33 dB. As well as the VBER or also called QEF between
2.00E-4 and 1.00E-6.
MENU "TOOLS"
This menu contains the tools that allow the communication and shipment of files
.PRO to the equipment. To do it, please follow the next steps.
Connect using the serial port RS-232C (Equipment DIN Rail) or Ethernet (19 "
Rack) the PC.
Page 18
USER'S MANUAL. PROWATCH
Figure 14.-
Figure 15.-
TELMO
03/2008

Capítulos

Tabla de contenido
loading

Tabla de contenido