Connection cards
1 Connect the corresponding gas inlet (see section 4.1)
in accordance with current regulations in the country
where the heater is being installed.
Connect using a rigid
shut-off valve between the installation and the unit
3 Once the connection to the gas network is comple-
te, check that all gas connections are tight. For this
purpose, a tightness test must be performed. To avoid
damage to the unit due to excess pressure, leave the
gas inlet valve closed.
Check that the supplied pressure and gas delivery va-
lues are those indicated for the unit's consumption. See
the technical data table (section 4.4).
The pipe must comply with applicable regulations.
Avoid areas with heat emissions.
Prevent the pipe from bending or being pinched shut.
The connections on both sides (gas valve and other
components) must comply with the regulations of the
country where the heater is installed.
The unit's power cable may not be replaced by the user.
If the cable is damaged, turn off the unit and call the
-
authorized technical support center to have it replaced.
To replace the cable, use only the 3x0.75mm
VV-F cable, with a maximum outer diameter of 8 mm.
This is a type C unit, with a sealed chamber and
be connected to systems such as those indicated below.
adding a
gurations shown on the technical data card (some of the-
.
rations may be limited or prohibited by local laws,
standards, or regulations. Before performing the installa-
tion, carefully check and observe any such restrictions.
Also observe all provisions regarding placement on walls
and/or ceilings and minimum distances to windows,
walls, air vents, etc. (section 2.2).
Before performing the installation, verify the diaphragm
cod. 3541S170 - Rev. 00 - 02/2019
-
-
-
-
-