Divert mode:
This field enables or disables call diverting.
O
For the user's convenience, the interface has an input for connecting an optional external switch.
O
This switch allows call diverting to be easily enabled or disabled.
Number of divert:
This field configures the number of telephones that the interface will try to call when call diverting is
O
enabled.
Can be configured for one, two or three telephones.
O
Maximum of 3 diverts in 4+N systems.
O
Maximum of one divert in 4+N CO systems.
O
No more than 2 diverts are recommended for Plus systems.
O
Priority call (Divert mode):
If a divert call occurs, and the number of diverts available is greater than one, this field will indicate
O
the order in which the calls are made.
Depending on the configured field value, one of the following call sequences will be used:
O
Field value "1": Phone.1, Phone.2, Phone.3
Ü
Field value "2": Phone.2, Phone.3, Phone.1
Ü
Field value "3": Phone.3, Phone.1, Phone.2
Ü
The automatic dialling sequence ends when one of the calls is answered.
O
The automatic dialling sequence ends when none of the calls are answered.
O
Lock release time:
The opening time of the lock release can be configured to have an activation interval between "01"
O
and "60" seconds.
This function is only applicable to 4+N audio door entry systems.
O
Auxiliary relay type:
The telephone interface has a potential-free relay output which can actuate auxiliary devices of the
O
audio door entry system installation such as (bells, lights,...) .
This relay output can be configured with the following field values:
O
"0" monostable type. In this option the user activates the relay (see page 55) and the interface
Ü
automatically deactivates it after the time configured in the "monostable time" field passes.
"1" bistable type. In this option the user activates and deactivates the relay (see page 55).
Ü
Auxiliary relay monostable time:
This option is only available if the auxiliary relay has been configured as monostable in the
O
"auxiliary relay type" configuration field.
Establishes the time that the relay remains active, this time can be configured between "01" and
O
"60" seconds.