Programming Fields; Description Of The Programming Fields - golmar IT-4N Manual De Instalación

Interfaz telefónico
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

PROGRAMMING

Programming fields:

OAdjustable system parameters.
Field
PIN entry
PIN change
Divert telephone 1
Divert telephone 2
Divert telephone 3
Divert mode
Number of divert
Call (divert mode)
Lock release time
Auxiliary relay: Type
Auxiliary relay: Monostable time
Auxiliary relay: State
Ring type
Reset local telephone volume
Reset volume of divert telephone
Door entry system sensitivity
System compatibilities
Divert type
Pick up detection

Description of the programming fields:

PIN entry:
To access the programming menu enter "##0" followed by the PIN "123".
O
This PIN has three digits.
O
This field stores the corresponding PIN.
O
PIN change:
The user can change the PIN in this field by accessing the programming mode and entering
O
the new PIN two times. If the new PIN is not repeated correctly the process will have to be
done again.
Divert telephone:
Each field stores a phone number which the audio door panel will call when the system has the
O
divert mode enabled.
Up to 16 digits from the sequence "0,1,2,3,4,5,6,7,8,9,#, "can be used
O
The "#" character creates a pause in the dialling (when calls are made via a PABX,
O
certain models may require this).
The " " character indicates the end of the programmed telephone number.
*
O
If the call is not answered, the next programmed telephone number is called,
O
and so on until a maximum of three numbers is reached.
Calls can be diverted to telephones on fixed-line or cellular networks, or to extensions on private
O
telephone networks, with this last option requiring the PABX to be installed in the same system as
the telephone interface
Code
"##0"
The PIN has three digits.
"00"
New PIN <3 digits>, repeat the PIN <3 digits>
"10"
Enter the telephone number, 16 digits maximum.
"11"
Enter the telephone number, 16 digits maximum.
Enter the telephone number, 16 digits maximum.
"12"
"15"
"0": Disabled; "1": Enabled.
"16"
"1": Divert to one ph.; "2": Divert to two ph.; "3": Divert to three ph.
Calling order: "1"; "2"; "3".
"17"
"20"
Between "01" and "60" seconds.
"0": Monostable; "1": Bistable.
"30"
"31"
Between "01" and "60" seconds.
"0": Normally open; "1": Normally closed.
"32"
"1": Cadence type; "2": Cadence type; "3": Cadence type.
"40"
"51"
Volume to default value, local telephone
"52"
Default volume, divert telephone "1"; "2"; "3" according to ph.
"60"
"1": High; "2": Medium; "3": Low.
"70"
"0": 4+N or 4+N Busy channel; "1":Plus System
"0": Normal Operation; "1": PABX, non-transparent.
"71"
"0": Automatic; "1": Manual.
"72"
.
Field value
*
51
Tabla de contenido
loading

Tabla de contenido