Main Supply
Voltage
Current type
Connected load
Protection (slow)
Type of protection
Protective class
Maximum allowed net impedance
Water connection
Max. feed temperature
Min. feed volume
Suck height from open container (20 °C)
Max. feed pressure
Performance data
Water flow rate
Operating pressure of water (using standard nozzle)
Max. excess operating pressure (safety valve)
Steam flow rate
Max. operating pressure for working with steam (using
steam nozzle)
Part no. of steam nozzle
Max. operating temperature of hot water
Working temperature steam operation
Detergent suck in
Burner performance
Maximum consumption of heating oil
Max. recoil force of trigger gun
Size of standard nozzle
Values determined as per EN 60335-2-79
Noise emission
Sound pressure level L
Uncertainty K
pA
Sound power level L
Hand-arm vibration value
Hand spray gun
Spray lance
Uncertainty K
Fuel
Fuel
Amount of oil
Oil grade
Dimensions and weights
Length x width x height
Typical operating weight
Fuel tank
Detergent Tank
24
Technical specifications
pA
+ Uncertainty K
WA
WA
HDS 9/18
V
380
Hz
3~ 50
kW
6,4
A
16
--
IPX5
--
I
Ohm
--
°C
30
l/h (l/min)
1200 (20)
m
0,5
MPa (bar)
0,6 (6)
l/h (l/min)
450-900 (7,5-15)
MPa (bar)
3-18 (30-180)
MPa (bar)
21,5 (215)
l/h (l/min)
390-450 (6,5-7,5)
MPa (bar)
3,2 (32)
--
2.114-004.0
°C
98
°C
155
l/h (l/min)
0-54 (0-0,9)
kW
75
kg/h
5,8
N
28,2
--
050
dB(A)
71
dB(A)
2
dB(A)
88
m/s
1,0
2
m/s
3,6
2
m/s
1,0
2
--
Fuel oil EL or Diesel
l
0,75
--
SAE 90
mm
1330 x 750 x 1060
kg
165
l
25
l
10+20
– 9
EN
HDS 12/18
380
3~ 50
8,4
16
IPX5
I
(0,163+ j0,102)
30
1500 (25)
0,5
0,6 (6)
600-1200 (10-20)
3-18 (30-180)
21,5 (215)
550-600 (9,1-10)
3,2 (32)
2.114-009.0
98
155
0-72 (0-1,2)
100
7,7
37,6
068
73
2
90
1,5
4,8
1,0
Fuel oil EL or Diesel
1,0
SAE 90
1330 x 750 x 1060
192
25
10+20