Technical Data - Hergom E-10 PLUS Instrucciones Para Instalación, Uso Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Below is a list of common problems in all types of stove. All of these problems can be rectified
and sometimes only require slight adjustment for the stove to function normally again.
Remember that the weather affects the functioning of the stove.
If your stove has vapour leaks to the interior of the house, it is most likely that the following
has occurred:
- If the chimney is newly built:
a) The flue is insufficient.
b) The section or height is not correct.
c) There is some obstruction in the unit.
-
If it is an existing chimney:
a) The chimney is partially obstructed with soot.
b) An internal or external breakage has occurred producing an air intake.
c) There is a lower section or height than is required by the new appliance.
We recommend reading the chapter titled, INSTALLATION MANUAL, and revising all
the information referring to Chimneys.
Specifications of the HERGÓM heater mod. E-10 PLUS.
Maximum heat power transferred
Accepts logs of the following length:
Door:
Fumes ring
Metal Chimney
Recommended chimney height*.
Brickwork chimney.
Performance
Mass flow rate of smoke
Average temperature of smoke;
Temperature exhaust gas ring
Minimum draw recommended:
Smoke outlet
Primary Air Control
Secondary air intake
Net weight
Gross Weight
(*) In the case of other heights consult your Dealer or the manufacturer (Approximate values)
Recommended fuel:
Fuel
Beechwood
Oak
Pine wood
ATTENTION! Your device should not be used as an incinerator and no other types of
fuel should be used (plastic, coal...). Use recommended materials only.
Do not wood washed ashore from the sea as fuel. The salt contained in it will react in the
combustion process and release acid that will damage the iron and steel.
2.5 – FLUE PROBLEMS

6.- TECHNICAL DATA

Dimensions L x Ø
40cm x 7cm (approx.)
40cm x 7cm (approx.)
40cm x 7cm (approx.)
36
7.5 kW
500 mm.
Height
300 mm.
Width
500 mm.
150 mm.
150 mm.
5 to 6 metres
150 x 150
65 %
11 g/sec
310 ºC
316 ºC
12.5 Pa
Vertical
Manual regulation
Venturi System
92 Kg.
100 Kg.
Maximum load per hour E-10-PLUS
3 Kg.
3 Kg.
3 Kg.
Int.
Tabla de contenido
loading

Tabla de contenido