 Afterwards you must calibrate the digital
 Then press the "Cal" calibration button 10
 Turn the digital level 180° around the ver-
 Then press the "Cal" calibration button 10
Note: If the digital level is not turned around
the axis shown in the figure in steps and ,
then the calibration cannot be completed
("CAL2" is not indicated in the display).
The vertical surface used to calibrate the tool
cannot slope more than 5°.
greater than 5°, the calibration is discontinued
and "---" will display.
 Switch the digital level on and place it
 Then press the "Cal" calibration button 10
 Turn the digital level 180° around the ver-
 Then press the "Cal" calibration button 10
 Afterwards you must calibrate the digital
 Then press the "Cal" calibration button 10
 Turn the digital level 180° around the ver-
 Then press the "Cal" calibration button 10
Note: If the digital level is not turned around
the axis shown in the figure in steps  and
, then the calibration cannot be completed
("CAL2" is not indicated in the display).
Changing the Unit of Measure (see figure A)
You can change between the units of measure
"°", "%" and "IN/FT" at any time. For this, press
the button for changing the unit of measure 8
as often as required until the desired setting is
10
2610039976 GIM60 GIM120.indd 10
level has now been recalibrated for this sur-
face.
level for the opposite surface. For this, turn
the digital level around its horizontal axis so
that the spirit level 1 faces downward and
the display 5 faces you. Place the digital
level onto the horizontal surface. Wait for
10s.
until "CAL1" appears briefly on the display.
Then the measuring value will flash on the
display.
tical axis so that the spirit level still faces
downward but the display 5 is facing away
from you. Wait for 10s.
again. "CAL2" will be shown on the display.
Then the measuring value (no longer flash-
ing) will appear on the display. The digital
level has now been recalibrated for both
horizontal surfaces.
Calibration for Vertical Surfaces
(see figure D)
against the vertical surface so that the
spirit level 6 faces upward and the display
5 faces you. Wait for 10s.
until "CAL1" appears on the display. Then
the measuring value will flash on the dis-
play.
tical axis so that the spirit level still faces
upward, but the display 5 faces away from
you. Wait for 10s.
again. "CAL2" will be shown on the display.
Then the measuring value (no longer flash-
ing) will appear on the display. The digital
level has now been recalibrated for this sur-
face.
level for the opposite surface. For this, turn
the digital level around its horizontal axis
in such a manner that the spirit level 6 fac-
es downward and the display 5 faces you.
Place the digital level against the vertical
surface. Wait for 10s.
until "CAL1" appears on the display. Then
the measuring value will flash on the dis-
play.
tical axis so that the spirit level still faces
downward but the display 5 is facing away
from you. Wait for 10s.
again. "CAL2" will be shown briefly on the
display. Then the measuring value (no lon-
ger flashing) will appear on the display. The
digital level has now been recalibrated for
both vertical surfaces.