Installer Setup - Honeywell PRO 4000 Serie Instrucciones De Instalación

Ocultar thumbs Ver también para PRO 4000 Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Installer Setup

Follow the procedure below to configure
the thermostat to match the installed
heating/cooling system, and customize
feature operation as desired.
To begin, press and hold the
buttons until the display changes.
• Press
to change settings.
t
• Press
to advance to next
s
function.
• Press and hold
save settings.
Setup function
1
System type
TH4110D only
5
Heating cycle rate
(CPH: cycles/hour)
TH4110D only
6
Auxiliary heat
cycle rate (CPH)
TH4210D only
8
Emergency heat
cycle rate (CPH)
TH4210D only
9
Compressor
cycle rate (CPH)
13 Adaptive Intelligent
Recovery
TM
14 Temperature
display
15 Compressor
protection
and
s
t
to exit and
ts
Settings & options (factory default in bold)
0
Gas, oil or electric heat with air conditioning
1
Heat pump (5 minute compressor off time in heating and
cooling)
5
For gas or oil furnaces of less than 90% efficiency
1
For steam or gravity systems
3
For hot water systems & furnaces of over 90% efficiency
9
For electric furnaces
[Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]
5
For gas or oil furnaces of less than 90% efficiency
1
For steam or gravity systems
3
For hot water systems & furnaces of over 90% efficiency
9
For electric furnaces
[Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]
9
For electric emergency heat
1
For steam or gravity systems
3
For hot water systems & furnaces of over 90% efficiency
5
For gas or oil furnaces of less than 90% efficiency
[Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]
3
Recommended for most compressors
[Other cycle rate options: 1, 2, 4, 5, or 6 CPH]
1
On
0
Off
0
Fahrenheit
1
Celsius
5
Five-minute compressor off time
[Other options: 0, 1, 2, 3 or 4-minute off time]
1
Function
number
5
Setup
0
Setting
MCR29341