MINIART R INSTALLATION
PRE-INSTALLATION CHECK LIST
The gate leaves must be firmly fixed to the hinges on the gate pillars,
they must not flex during the movement and they must swing without any
friction. Before installing the operator, make sure you have enough room
to fix the operator on the pillar.
In case the gate is like the one depicted in Pic. 1, there is no need for any
modification.
Gate features and installation must comply with local regulations and
standards.
The gate can be automated only if it is in good conditions and complies
with EN12604 norms.
- The gate leaf must not have a pedestrian door in its structure. Should
there be a pedestrian opening, take the appropriate steps according to
EN12435 norms (e.g. cutting out the motor when the pedestrian door is
opened by fixing a safety micro switch connected to the control board).
- Make sure not to create any trapping points or areas (e.g. when the gate
completely opened, between any opening in the gate frame and the side wall).
EMERGENCY MANUAL RELEASE
This applies only if the unit is not equipped with back-up batteries. In case
of a black-out, the gate can be pulled open after the operator has been
unlocked with the emergency key provided (rotate the key clockwise by
180°, Pic. 2).
EMERGENCY MANUAL RELEASE THROUGH AN EXTERNAL STRONG
BOX
In case of a black-out, should you need to unlock the gate from outside
through an external Strong Box, secure one end of the steel cord with
sheath (A) to the unlocking lever (B) on the operator, and the other end to
the unlocking device (C) inside the strong box, as in Pic. 3.
CAUTION
In order to manually open the gate leaf make sure of the following:
- The gate leaves must be endowed with appropriate handles;
- Position of the handles onto the gate leaves must be in risk free area;
- The manual force necessary to move the gate leaves should not be
higher than 225 N, in case of installations at domestic/private dwellings,
and 390N in case of installations in business premises (according to
points 5.3.5 of the EN12453 norm).
Note: in case of an installation with an overlapping two leave swing gate,
to ensure a safe/proper locking, a mechanical bolt must be installed along
with an electric lock. The mechanical bolt must be installed at the bottom
of the first gate leaf to close so that it will be triggered by the pressure of
the second gate leaf. The electric lock will latch one gate leaf to the other.
B
6-1624105
rev. 6
FRA
ENG
19/03/2018
Parts to install meeting the EN 12453 standard
COMMAND TYPE
with manned
operation
with visible
impulses
(e.g. sensor)
with not visible
impulses
(e.g. remote control
device)
automatic
* a typical example are those shutters which do not have access to
any public way
A: Command button with manned operation (that is, operating as
long as activated)
B: Key selector with manned operation
C: Adjustable power of the motor
D: Safety strips and/or other safety devices to keep thrust force
within the limits of EN12453 regulation - Appendix A.
E: Photocells, (To apply every 60÷70cm for all the height of the
column of the gate up to a maximum of 2,5m - EN 12445 point
7.3.2.1)
B
ESP
ITA
DEU
USE OF THE SHUTTER
Skilled
Skilled
persons
persons
(out of public
(public area)
area*)
A
B
C or E
C or E
C and D,
C or E
or E
C and D,
C and D, or E
or E
C
A
Unrestricted
use
non
possibile
C and D,
or E
C and D,
or E
C and D,
or E
2
3