EN
Instruction Manual
Pressing this command (7) and command ▲ (8) simultaneously for more than 5 seconds, all
alarms are reset.
Pressing this command (7) and the SET (3) command for more than 5 seconds simultaneously
accesses the parameter setting menu (C)
To change the parameters C or F once within the selected menu, move through the parameters
with the cursors ▲ (8) and ▼ (9) until you reach the parameter to be modified or the sound and
alarms key (7) to display the menu complete to reach the category more quickly. Pressing SET
(3) selects the category or parameter to modify and is modified by ▲ (8) and ▼ (9). Once all the
desired parameters are modified, they are memorized by pressing the sounds and alarms
command (7) for more than 5 seconds. If nothing is pressed in 60 s you lose the Co F menu by
losing data that has not been saved.
Pressing this command ▲ (8) and the SET (3) command simultaneously for more than 5 seconds
activates the printout of the report.
BASIC PARAMETERS MODIFIED BY THE USER.
"Pro"
Pw (Password): Default value 22.
/ 5 (Selection ºC or ºF): Default value ºC.
"CtL"
St (Setpoint): Default value per model. Modify if applicable.
"ALM"
AL (Low temperature alarm activation): Default value 0 (disabled).
AH (High temperature alarm activation): Default value 0 (disabled).
"CnF"
H2 (Keyboard Disable): Default value 1.
4.3 MACHINE SETTINGS AND PROGRAMS
HEATING SYSTEM:
The heating is generated by means of hidden heating elements installed in the lower part of the
vitro-ceramic glass.
In the case of model DC6/7-PP2/ DC6/7-PPW2, the foodhshield includes an ECO halogen lamp
(energy saving) which provides light and heat to the food displayed in the top part as a
supplement to the heating of the panel.
WORKING TEMPERATURES: described in table 1.
[14]