Installation And Assembly; Connections; Operation; General Information - edenox DROP IN Manual Del Usuario

Vitrocerámica (+con pantalla de calor) / plaque
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

EN

3.5 INSTALLATION AND ASSEMBLY

Avoid having direct sources of heat, cold, humidity, sunlight and ultraviolet rays in the final
location of this appliance. Heaters, radiators, air conditioning, air currents etc. can have a
negative influence on the correct operation of the same.

3.6 CONNECTIONS

Make sure the floor is level, in this way preventing any vibration or noise.
Follow the instructions shown in figure 1 to 3 to install the product in the selected place and do
the required connections.
In figure 4 it is described how to take out the product of the installed place to do maintenance
and the figure 5 and 7 describes, if necessary, how to displace the control panel from its current
position to the desired position. It can't be relocated further than 1,6m.

4 OPERATION

4.1 GENERAL INFORMATION

The temperature control is carried out by a digital electronic thermostat, allowing to adjust the
different working temperatures of the appliance depending on the existing environmental
conditions.

4.2 CONTROL PANEL DESCRIPTION

1- Display
2- Main On-Off buttom (except light)
3- Set
4- ECO function
5- Light On-Off
6- Programing and disconnect sound/ alarm
7- Up ▲
8- Down ▼, manual defrosting (only in refrigeration)
The machine is switched on by pushing the on-off bottom of the thermostat for 5 seconds. For
maintenance operations, disconnect the machine from the mains, because the machine is in
stand-by situation when it is switch off.
The regulation is made by electronic thermostat with a digital display, allowing to adjust the
different working temperatures of the machine:
Pressing the SET (3) command for 1 second activates the set point to reach the desired
temperature value displayed on the Display (1). To do this, press the cursors (8 or 9) ▲ ▼ until
the desired temperature is reached. Once reached, press and hold the SET (3) command for 1
second to set the acquired value.
It is possible to activate the ECO mode (5) energy saving by pressing for 3 seconds this key.
When activated, ECO will appear in the display (1). To return to the normal state, perform the
same operation. This will display the word NOR in the display (1).
It is possible to activate or deactivate the light output by pressing the LIGHT (6) command for 1
second.
To access the sounds and alarms program (7), press and hold for more than 5 seconds. The
parameter setting menu (F) will appear in the display (1) or in case of alarms, the alarm will be
silenced and the alarm relay will be deactivated.
Instruction Manual
[13]
Tabla de contenido
loading

Tabla de contenido