Possible Remedy
1a. Remove disposable filter bag or empty debris bucket as described in pages 3-4 and install replacement.
1b. Insert handle end of hose into utility valve at power unit. Turn unit on. This will reverse normal air flow through the hose and
dislodge any clogs.
1c. Insert hose end into any inlet with power unit running, place the palm of your hand over the opposite end of the hose. When
you can feel the suction increase, hold your hand over the hose end for a few seconds and then quickly remove your hand.
This procedure repeated several time should clear the obstruction. If the blockage is not cleared, contact your nearest
Service Center.
1d. Check all wall inlet covers to be sure they are closed and sealed tightly.
1e. Inspect and remove any blockages.
2a. Replace defective wall inlet.
2b. Turn unit off for 20 minutes then plug unit back in. If unit does not start, look for the tripped circuit breaker behind the unit,
a white button has popped up, push it back to reset it. If circuit breaker trips again, unplug your unit and contact your local
Service Center.
2c. Replace fuse or reset circuit breaker on wall panel.
2d. Replace hose as required.
2e. 1) Push Reset button while unit is engaged OR
2) Unplug unit completely for 60 seconds.
2f. Contact your local Service Center.
3a. A complete check of all wall inlets and power unit low voltage control lead connections. Contact your local authorized
Service Center.
4a. Change filter bag. Be sure to push the bag full Reset button located on the front of the unit.
5a. Contact your local authorized Service Center.