• Inspect the cable tension. For systems that utilize a compression spring (Figure ?), the spring
in the bottom bracket should be compressed to 5-1/2 inch (13.8 cm) length. For systems that
utilize a tension rod and tension indicator washer (Figure 21), the washer should be indicated
(center ridge sheared off) and the washer imbedded fully into hole of bottom bracket. You
should not be able to pull tension rod down by hand. Cable should be tight enough to prevent
contact with the ladder/structure. Re-tension the cable if necessary. For bottom brackets that
contain an indicating washer, a new washer (part no. 9504239) should be installed if the cable
is re-tensioned. Tighten the system until indicating washer ring is sheared off. Do not over-
tension the system.
Installation and Service Label: See Section 8 and Figure 13.
• Inspect the installation and service label. The label should be securely attached and fully
legible. The installation date and number of users allowed on the system should be clearly
marked on the label. Record the inspection date on the label after inspection is completed.
Ladder/Climbing Structure:
• Inspect the ladder/climbing structure to which the Lad-Saf
the structure is in good condition, secure, and safe to climb. If the condition of the structure is
questionable, consult instructions and/or personnel familiar with the structure prior to use.
5.3 INSPECTION GUIDELINES - LAD SAF
Inspect the LAD-SAF
Instructions. LAD-SAF
LS-1
6116541
(ANSI A14.3,
CSA Z259.2.1)
LS-2
6116540
(ANSI A14.3,
CSA Z259.2.1)
LS-3
6116507
(CSA Z259.2.1)
LS-4
6116535
(ANSI A14.3,
CSA Z259.2.1)
LS-5
5.4 If inspection reveals an unsafe or defective condition remove the ladder safety system or the safety sleeve
from service and destroy it or contact an authorized service center for repair.
5.5 I-SAFE™ RFID TAG:
The Lad-Saf
system includes an i-Safe™ Radio Frequency Identifi cation (RFID) tag (Figure 12).
®
The RFID tag can be used in conjunction with the i-Safe handheld reading device and web based
portal to simplify inspection and inventory control and provide records for your fall protection
equipment. If you are a fi rst-time user, contact a Capital Safety Customer Service representative
(see back cover); or if you have already registered, go to http://isafe.capitalsafety.com. Follow
the instructions provided with your i-Safe handheld reader or on the web portal to transfer your
data to your web log.
6.0 MAINTENANCE, SERVICING, STORAGE
6.1 The LAD-SAF
installation requires no scheduled maintenance. See section 5.0 for inspection related
®
maintenance issues. If the carrier cable becomes heavily soiled with oil, grease, paint, or other substances,
clean it with appropriate cleaning solutions. Do not use acid or caustic chemicals that could damage the
cable.
DETACHABLE CABLE SLEEVE:
®
detachable sleeve per the inspection steps defi ned in the associated User
®
sleeve models and their respective User Instructions (See Figure 5):
®
6116507
(EN353-
1:2002)
6116535
6116535
(EN353-
(VG-11
1:2002)
CNB/P/11.073)
6160031
6160031
(EN353-
(VG-11
1:2002)
CNB/P/11.073)
system is attached. Make sure
®
Flex Sleeve, 8.0 mm or 9.5 mm
(5/16" or 3/8"), Sleeve Only
Flex Sleeve, 8.0 mm or 9.5 mm
(5/16" or 3/8"), w/Carabiner
Flex Sleeve, 8.0 mm or 9.5 mm
(5/16" or 3/8"), w/Shock Pack & Carabiner
Flex Sleeve, 8.0 mm or 9.5 mm
(5/16" or 3/8"), w/Carabiner
Flex Sleeve, 8.0 mm or 9.5 mm
(5/16" or 3/8"), w/Snap Hook
13