Consideraciones Previas - Roca AQUAKIT NEOBASIC Instrucciones De Instalación

E

1. CONSIDERACIONES PREVIAS

- Tipo de agua: potable (Ver figura ).
Depósitos acumuladores:
Para depósitos acumuladores inferiores a 00 litros se reco-
mienda elevar el termostato hasta el máximo valor admisible,
ya que en caso contrario la duración del hidromasaje con agua
caliente quedará reducida a pocos minutos. Por cuestiones de
seguridad este valor no deberá sobrepasar los 60°C.
Calentadores instantáneos:
Si se dispone de un calentador instantáneo o caldera mixta
deben garantizar las presiones y consumos indicados ante-
riormente. Potencias útiles inferiores a 0.000 Kcal/hora no
podrán mantener temperaturas elevadas durante determi-
nadas funciones, registrándose una pérdida de caudal o de
temperatura.
Si se le apaga la caldera y le sale agua fría, ajuste la tempera-
tura y caudal de la caldera de forma adecuada, en caso de no
conseguirlo consulte al servicio post-venta de la caldera.
Sistemas mixtos calentador instantáneo con depósito
acumulador:
Es la configuración recomendada, con un volumen de depósi-
to no inferior a 50 litros.
Otras consideraciones (ver figura ).
Fig. 
Schéma 
Abb. 
GB
1. PRELIMINARIES
- Type of water: drinking. (See figure ).
Accumulator tanks:
If the hydromassage is going to be supplied from an accumu-
lator tank with a capacity of less than 00 litres, we recom-
mend that you turn the thermostat to the highest possible
temperature setting. Otherwise the supply of hot water is only
likely to last for a few minutes when the hydromassage is in
operation. For safety reasons a temperature of 60°C. must not
be exceeded.
Instant heaters:
If using an instant heater or combination boiler, they must guar-
antee the pressure and consumption levels stated above. If the
output power is less than 0,000 Kcal/hour, high temperatures
cannot be maintained during certain functions, and a loss of
pressure or temperature will be noted.
If the boiler switches off and cold water comes out, adjust the
temperature and the flow of the boiler as required. If you do
not manage to solve the problem, please consult the boiler's
after-sale service
Mixed systems with an instant heater and an accumulator
tank:
This is the recommended system, with a tank volume of no
less than 50 litres.
For further reference, refer to figure . .