DANGER: Never connect the generator set earthing wire to piping. In addition, the piping
!
is carrying flammable substances such as gas or fuel oil, there is always a risk of a fire
or explosion in the event of a short-circuit.
RECEIPT AND HANDLING
On receipt of your generator set, check that the equipment is in good condition
and that your order is complete. The generator should be handled with care and
no sudden movements, after preparing the area for its storage or use in advance.
Never try to start the generator before carrying out the preparation as described in
!
section 2 of the manual
EARTHING :
Earth the generator set each time it is used to prevent electrocution. For this purpo-
se, use a 10 mm2 copper wire attached to the generator's earth connector and a
galvanised steel earth rod inserted 1 metre into the ground (equipment not sup-
plied with generator set). This earthing also dissipates the static electricity genera-
ted by electrical machinery.
118030-Manual-C.indd 24
:
EN
6/09/11 10:55:05