G
B
TECHNICAL DATA / INSTALLATION SER
TECHNICAL DATA
Max gate weight
Max gate surface
Limit switch winding capacity
Nominal functioning torque
Max operating torque
Max lifting force from earth
Max operating force
Pulley revolutions
Pulley diameter
Shaft diameter
EEC Power supply
Motor capacity with load
Power absorbed with load
Capacitor
Functioning cycles
Daily operations suggested
Service
Nominal functioning time
Motor weight
Working Temperature
Protection
*
*
SER 20
Ø 200 / 7,8
SER 22
Ø 220 / 8,6
SER 22S
Ø 220 / 8,6
SER 24
Ø 240 / 9,4
R
OLLING GATE CONTROL
The European Standard EN 12604 "Industrial, Commercial and Garage Doors
and Gates - Mechanical Aspects - Requirements", at the point 4.3. "Protection
against unintentional and uncontrolled movements" requires also that*:
a - The vertically operating door leaves shall be balanced so that the door
leaf can stop in any position, or that the out-of-balance state shall not
produce, in any case, a static force at the primary closing edge of the
door exceeding 150N (15,3 kg / 33,70 lbs).
Verify it after having manually released the SER operator.
b - If a spring fails, the resulting out-of-balance static force occurring at
the primary closing edge of the roller shutter shall not exceed 200N
(20,4 kg / 44,94 lbs), even when the SER operator is manually released.
After this failure, you must intervene on the door to substitute the
broken spring and correct the balance state. Therefore, we suggest
you to fraction the roller shutter weight with an adequate number of
springs (* This is a free interpretation).
WARNING: The EN 12445 standard "Industrial, commercial and garage
doors and gates - safety in use of power operated doors - test methods"
at point 4.1.2 "safeguarding against hazard of being lifted" provides that
the rolling gate shall not be able to lift more than 20 kg / 44 lbs. In order
to meet this standard, ALLMATIC suggests to install a control board with
electric power regulation.
6-1624000 REV. 09 DEL 05/03/13
326 / 12,8
41 / 1,6
**
**
SER 20
ø 48 / 1,9
SER 22
ø 60 / 2,3
SER 22S
ø 60 / 2,3
SER 24
ø 76 / 2,9
Measurements in mm/inch
SER 20
kg/lbs
220/485
2
m
16
N°rotat.
9,5
Nm
150
Nm
110
kg/lbs
150/330
kg/lbs
110/242
rpm
11
mm/in
200/7,8
mm/in
48/1,8
W
620 / 450
A
2,78 / 4,1
µF
20 / 60
N°
7 - 20s/2s
N°
20
s
330
kg/lbs
8,5
°C
IP
PARTS TO INSTALL MEETING THE EN 12453 STANDARD
COMMAND TYPE
(out of a public area*)
with manned operation
with visible impulses
(e.g. sensor)
with not visible impulses
(e.g. remote control device)
automatic
* a typical example are those shutters which do not have access to any public way.
A: C ommand button with manned operation (that is, operating as long as activated).
B: Key selector with manned operation.
C: Motor force regulation.
D: S afety edges or Sensor able to detect an obstacle and/or other safety devices to
keep thrust force within the limits of EN12453 regulation - Appendix A.
E: P hotoelectric cells, (To apply on the whole height of the door up to max 2,5 m as
indicated on EN 12445 point 7.3.2.2).
I
N ORDER TO ENSURE A CORRECT FUNCTION ONLY
ALLMATIC'S COMPONENTS MUST BE USED
1 - SER operator
2 - Photoelectric cells (external)
3 - Push-Button
14
14
SER 22
SER 22 S
280/617
24
8,5
165
200
120
165
160/352
190/418
110/242
150/330
10
220/8,6
60/2,3
230V ~ 50Hz / 120V ~ 60HZ
600 / 500
2,8 / 4,16
20 / 60
14 - 20s/2s
30
30%
630
9,5
10
-10 ÷ +70
300
USE OF THE SHUTTER
Skilled persons
Skilled persons
(public area)
A
B
C or E
C or E
C or E
C and D, or E
C and D, or E
C and D, or E
4 - Key selector
5 - Tuned aerial
6 - Flashing lamp
SER 24
7,5
290
200
240/528
165/363
9
240/9,4
76/2,9
11
Unrestricted use
-
C and D, or E
C and D, or E
C and D, or E