Technical Data; Electrical Installation - Grohe 36 277 Manual De Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
GB
Safety notes
Prevent danger resulting from damaged power
supply cables. In the case of damage, the power
supply cable must be replaced by the manufacturer
or its customer service department or an equally
qualified person.
• Installation is only possible in frost-free rooms.
• The optional power supply unit is only suitable for indoor
use.
• The plug-in connectors must not be directly or indirectly
sprayed with water when cleaning.
• The voltage supply must be separately switchable.
• The maximum permissible distance between the digital
controller and the functional unit is 5 m.
Application
Can be used in conjunction with:
• Pressurised storage heaters
Must not be used in conjunction with:
• Thermally controlled instantaneous water heaters
• Hydraulically controlled instantaneous water heaters
• Unpressurised storage heaters (displacement water
heaters)

Technical data

• Flow pressure:
- min.
- recommended
• Operating pressure:
• Test pressure:
A pressure-reducing valve must be fitted if static pressure
exceeds 0.5 MPa.
Avoid major pressure differences between hot and cold water
supply.
• Flow rate at 0.3 MPa flow pressure:
• Hot water supply temperature:
Recommended (energy saving):
• Voltage supply:
• Power consumption:
• Radio frequency:
• Transmitter power:
• Emergency power supply: 6 V lithium battery (type CR-P2)
• Digital controller battery:
3x 3 V lithium batteries (type CR 2450)
• Automatic safety shut-off (factory setting):
• Safety stop:
• Type of protection:
• Water connection:
Electrical test data
• Software class:
• Contamination class:
• Rated surge voltage:
• Temperature for ball impact test:
The test for electromagnetic compatibility
(interference emission test) was performed
at the rated voltage and rated current.
5
0.1 MPa
0.2 - 0.5 MPa
max. 1.0 MPa
1.6 MPa
approx. 9 l/min
min. 50 °C - max. 80 °C
230 V AC, 50/60 Hz
2.4332 GHz
< 1 mW
- Fitting
- Battery box
- Digital controller
cold on right/hot on left
2,500 V
100 °C
Approval and conformity
This product conforms to the requirements of the
relevant EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica

Electrical installation

Electrical installation work must only be performed
by a qualified electrician. This work must be
carried out in accordance with the regulations
according to IEC 364-7-701-1984 (corresponding
to VDE 0100 Part 701) as well as all national and
local regulations.
Installation
Install spout, see fold-out page II, Figs. [1] and [2].
Install pop-up waste (65 807), see fold-out page I.
Seal plug-hole rim.
Insert batteries into digital controller, see technical product
information for the digital controller. Insert batteries with
correct polarity.
The digital controller is registered with the functional unit in the
factory.
Fasten digital controller, see technical product information for
the digital controller.
The adhesive film must be allowed to cure for 24 hours before
the digital controller is removed for the first time.
Install functional unit, see Fig. [3].
Grease O-rings with the special grease supplied prior to
installation.
Flush pipes thoroughly before and after installation
(observe EN 806).
Connect functional unit, see Figs. [4] and [5].
60 °C
Open hot and cold water supply and check that connections
9 VA
are watertight. Water flows until the voltage supply is
established.
Connect battery housing to functional unit, see Fig. [4].
Establish voltage supply via plug-in power supply 65 790, see
fold-out page I.
The connecting wire can be extended using the extension
cable special accessory (Prod. no. 47 727). A maximum of two
60 s
extension cables can be joined together (max. 6 m).
42 °C
The reception can be improved and thermal disinfection
IP 66
carried out using the transceiver special accessory
IP 66
(Prod. no. 36 356).
IP 57
Approx. 10 seconds after the voltage supply is established
there are two brief water pulses and the buttons of the digital
controller are now inoperative for 60 seconds.
The fitting must be adapted to the local conditions, see section
B
Selection menu of the digital controller, F2 - Calibration.
2
Settings during power failure/when changing batteries
No settings saved by the user will be lost when changing the
batteries or in the event of an interruption of the power supply
to the functional unit.
Tabla de contenido
loading

Este manual también es adecuado para:

36 286

Tabla de contenido